(En anglais seulement) This item is a center piece of the Mach-1 mechanical tester. It presents a threaded post on its base on which can be fitted a large set of compatible sample holders. Two interchangeable transparent walls can be slide fitted to create an environmental chamber which can be filled by bathing solution.

Round test chamber with a 98mm inner diameter. The threaded base allows the user to fit a multitude of accessories helping to fix the sample. The sealed transparent walls allows the user to perform tests on submerged samples. Made of stainless steel 316L, this test chamber can be in contact with saline water without risk of oxidation. Comes with two swappable walls of 50.8 and 76.2 mm of height.

  • Cet accessoire a été conçu pour faciliter son nettoyage et sa désinfection.
  • Cet accessoire présente un design robuste procurant une longue durabilité
  • Compatible avec une utilisation en solution physiologique saline.
  • Facile à assembler et à monter sur le testeur
  • Design modulaire, ajustement facile pour chaque configuration de test.
  • Disponible avec une variété d’accessoires de base et personnalisés
  • Une clé d’alignement prévient la rotation du support à échantillon lors des tests en torsion
Matériaux

Stainless steel 316L, Clear Acrylic (Wall)

Hauteur

50.8 et 76.2 (parois)

Diamètre

98 mm

Fixation du bas

4X 1/4-20 Trous de vis

Fixation du haut

3/4-16 Poteau fileté ou 1/4-28 filet femelle et clé d’alignement

Documents et ressources (1)

Configurations de test (5)

FAQ

Comment fonctionne le modèle poroélastique en compression confinée "Poroelastic Model in Confined Compression"?
(En anglais seulement) This tool allows for the computing and visualizing of the aggregate modulus (MPa), the permeability (mm2/MPa·s) and the mean square error (RMSE) of the fit calculated from a “Stress Relaxation” curve (load or force vs. time) in confined compression (Figure 1) on a disk sample. The curve is fitted to the linear biphasic model (Mow et al., 1980 or Bursać et al., 1999) in order to obtain the mechanical properties of the disk. Sample radius, strain and sample thickness need to be specified.

This model is well adapted for the mechanical characterization of samples containing a liquid fraction and a solid matrix, for example: cartilage or gel samples. A user license is required in order to obtain the results of the poroelastic model in confined compression (Software Add-On, contact Biomomentum to obtain your license).

Mechanical properties can be obtained from the stress relaxation curves obtained under confined compression such as the aggregate modulus (HA) and the hydraulic permeability (k). The aggregate modulus is a measure of stiffness of the sample at equilibrium while the hydraulic permeability is the ability of the fluid to flow through the cartilage matrix.

For example, (Figure 2) shows parameters used for the “Stress Relaxation” function in a confined compression testing protocol on human cartilage disks. Corresponding results are shown in (Figure 1).

Mach-1 Analysis – Modèle poroélastique en compression confinée – Paramètres

Mach-1 Analysis – Modèle poroélastique en compression confinée – Exemple

Comment fonctionne le modèle poroélastique en compression non-confinée "Poroelastic Model in Unconfined Compression"?
(En anglais seulement) This tool allows for the computing and visualizing of the fibril network modulus (MPa), the equilibrium modulus (MPa), the permeability (mm2/MPa·s), and the mean square error (RMSE) of the fit calculated from a “Stress Relaxation” curve (load or force vs. time) in unconfined compression (Figure 1) on a disk or osteochondral core sample. The curve is fitted to the linear fibril-network-reinforced biphasic model (Soulhat et al. 1999) in order to obtain the mechanical properties of the disk. Sample radius, strain, and Poisson’s ratio need to be specified. This model is well adapted for the mechanical description of samples containing a liquid fraction and a fibril network, for example: cartilage or gel samples. A user license is required in order to obtain the results of the poroelastic model in unconfined compression (Software Add-On, contact Biomomentum to obtain your license).

The nonhomogeneous composite model (i.e. linear fibril-network-reinforced biphasic model) is an extension of the previously developed isotropic homogeneous biphasic model, and was achieved by reinforcing the latter with a network of nonlinear fibrils distributed homogeneously in the r, θ, z directions and which resist extension only (Figure 2). The isotropic matrix is described by the drained elastic constants Em (Young’s modulus), vm(Poisson’s ratio) and a hydraulic permeability k. The fibril network is described by the Young’s modulus of individual fibrils ef which, combined with a fibril volume fraction χ (fibrils volume/ total-volume), results in an equivalent tensile modulus of the fibril network, Ef = 1/3 χ ef (since 1/3 of the fibrils are oriented in each of three mutually orthogonal directions).

For example, (Figure 3) shows parameters used for the “Stress Relaxation” function in an unconfined compression testing protocol on ovine cartilage disks. Corresponding results are shown in (Figure 1).

Mach-1 Analysis – Modèle poroélastique en compression non-confinée – Paramètres

Mach-1 Analysis – Modèle poroélastique en compression non-confinée – Cartilage

Mach-1 Analysis – Modèle poroélastique en compression non-confinée – Exemple

Comment fonctionne le modèle "Sinusoid"?

(En anglais seulement) This feature is used to obtain the Frequency, Amplitude and Offset of a sinusoidal signal. A blue line displays the theoretical sinusoid with the Frequency, Amplitude and Offset obtained (Figure 1). The values of the Frequency, Amplitude and Offset are indicated in the "Results" field. The units vary according to the graph’s axes.

This feature can also be used for sinusoidal stimulus-response analysis. Sinusoidal stimulus shall be selected on the x-axis and the sinusoidal response on the y-axis. The Modulus is the ratio of the response Amplitude over the stimulus Amplitude. The Phase is the phase difference between the response and the stimulus. The Modulus’ is computed as the Modulus*Cos(Phase) and the Modulus” is computed as the Modulus*Sin(Phase). A blue line displays the theoretical sinusoidal stimulus-response with the Frequency, Modulus and Phase obtained (Figure 2). The values of the Modulus and Phase are indicated in the “Results” field. The units vary according to the graph’s axes.

One use for this feature would be to compute material properties by multiplying the Modulus obtained by the appropriate geometric factors. For example, the Young’s Modulus can be obtained during uniaxial compression or tension on cylindrical sample with t/pi*r2 as the geometric factor, t is the thickness and r is the radius of the sample.

Mach-1 Analysis – Sinusoid – Exemple d’analyse stimulus-réponse

Mach-1 Analysis – Sinusoid – Exemple d’analyse des signaux

Besoin d’aide pour choisir un accessoire ?

Parlez à notre équipe

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.