Aller au contenu

Evaluating the Irritant Factors of Silicone and Hydrocolloid Skin Contact Adhesives Using Trans-Epidermal Water Loss, Protein Stripping, Erythema, and Ease of Removal

  • par garon@biomomentum.com

Edward Dyson; Stephen Sikkink; Davide Nocita; Peter Twigg; Gill Westgate; Thomas Swift
ACS Appl. Bio Mater, Publication Date: December 27, 2023

https://doi.org/10.1021/acsabm.3c00874

11 citations · 10 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract

A composite silicone skin adhesive material was designed to improve its water vapor permeability to offer advantages to wearer comfort compared to existing skin adhesive dressings available (including perforated silicone and hydrocolloid products). The chemical and mechanical properties of this novel dressing were analyzed to show that it has a high creep compliance, offering anisotropic elasticity that is likely to place less stress on the skin. A participant study was carried out in which 31 participants wore a novel silicone skin adhesive (Sil2) and a hydrocolloid competitor and were monitored for physiological response to the dressings. Trans-epidermal water loss (TEWL) was measured pre- and postwear to determine impairment of skin barrier function. Sil2 exhibited a higher vapor permeability than the hydrocolloid dressings during wear. Peel strength measurements and dye counter staining of the removed dressings showed that the hydrocolloid had a higher adhesion to the participants’ skin, resulting in a greater removal of proteins from the stratum corneum and a higher pain rating from participants on removal. Once the dressings were removed, TEWL of the participants skin beneath the Sil2 was close to normal in comparison to the hydrocolloid dressings that showed an increase in skin TEWL, indicating that the skin had been highly occluded. Analysis of the skin immediately after removal showed a higher incidence of erythema following application of hydrocolloid dressings (>60%) compared to Sil2, (<30%). In summary, this modified silicone formulation demonstrates superior skin protection properties compared to hydrocolloid dressings and is more suitable for use as a skin adhesive.

Keywords:

Silicone, adhesive, skin contact, vapor permeability, TEWL, peel strength.

Utilisation des équipements

L’étude a évalué des adhésifs cutanés en silicone et hydrocolloïdes, notamment leur résistance au pelage et les réponses cutanées après retrait. Les méthodes disponibles attribuent les essais de traction uniaxiale à un Instron 5568, mais n’identifient pas l’appareil utilisé pour le pelage. Ces extraits ne permettent pas de vérifier le rôle ni le protocole du Mach-1 Mechanical Tester.

Matériaux (2)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.