Aller au contenu

Conducting polymer films and bioelectrodes combining high adhesion and electro-mechanical self-healing

  • par garon@biomomentum.com

Xin Zhou; Pierre Kateb; Jiaxin Fan; Jinsil Kim; Gregory A. Lodygensky; Bénédicte Amilhon; Damiano Pasini; Fabio Cicoira
Journal of Materials Chemistry C. 2024;12(16):5708–5717. First published 13 December 2023; issue 28 April 2024.

https://doi.org/10.1039/d3tc04230h

31 citations · 22 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Self-healable, conductive, soft, and stretchable electronic materials have become research hotspots in wearable and bioelectronic devices for healthcare monitoring. In this study, conductive, soft, stretchable, self-healing, highly adhesive, and biocompatible conductive polymer films were obtained by mixing poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS), ethylene glycol (EG), and tannic acid (TA). The films with optimized composition demonstrated very attractive properties for wearable electronics and bioelectronics, including a conductivity of ∼17 S cm−1, a low Young's modulus of ∼450 kPa, stretchability of ∼90% strain, outstanding electrical stability during stretching (2% resistance change at 30% strain), and strong adhesion on several substrates. Notably, the films exhibited outstanding autonomous and cut-stick healing properties, enabled by the addition of TA. Furthermore, the films exhibited no signs of cytotoxicity, making them suitable for biomedical applications. Epidermal electrodes prepared using these materials exhibit low skin-electrode impedance at low frequencies (1–100 Hz) and high quality for electrocardiography (ECG) and electromyography (EMG) signal recordings. This study promotes the development of innovative wearable biomedical devices and contribute to personalized healthcare monitoring.

Utilisation des équipements

Le Mach-1 a évalué des films conducteurs PEDOT/EG/TA par pelage à 90° sur du verre et de la peau porcine, ainsi que par traction avec mesure de la résistance électrique à l’aide de mors à électrodes.

Matériaux (1)

Configurations de test (3)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.