Aller au contenu

Technical Feasibility of an Ex Vivo Bovine Trabecular Bone-Titanium Implant Co-Culture Platform for Early Interface Studies

  • par garon@biomomentum.com

Coralie Nagels; Bianca Riedel; Sunil Shetty; Hagen Schmal; Martin P. Pichotka; Ralf Thomann; Michael Seidenstuecker
Journal of Functional Biomaterials. 2026;17(11):538. Published 23 October 2026.

https://doi.org/10.3390/jfb17110538

0 citations · 0 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Ex vivo bone organ cultures may bridge the gap between simplified in vitro systems and animal studies. This proof-of-concept study evaluated the technical feasibility of a bovine trabecular bone–implant co-culture platform over 21 days. Thirty-two bone cylinders from three donors were cultured with porous Ti6Al4V implants. A central 6 mm channel reduced the maximum theoretical radial diffusion distance to approximately 2.5 mm. Wurtzite and diamond architectures were coupled to experimental run and femoral laterality, precluding independent evaluation of architecture-dependent biological effects. Constructs received no load, sustained static load, or static load combined with daily or weekly dynamic compression at 1 Hz for 300 cycles per session. Loaded assemblies comprised four constructs beneath a shared plate; individual forces, stresses, and strains were neither measured nor independently controlled. Metabolic activity, viability, histology, bone volume fraction, immunofluorescence, and implant colonization were assessed. Structural comparisons were cross-sectional. Metabolic activity initially decreased before increasing from day 7 onward, and viable cells and extensive implant colonization were observed after 21 days. No loading-dependent biological or structural differences were detected. The findings support technical feasibility but do not establish mechanobiological sensitivity. Further validation requires specimen-specific mechanical monitoring, re-optimization of loading parameters, and quantitative biological endpoints.

Utilisation des équipements

Un Mach-1 appliquait une stimulation cyclique en compression (1 Hz, 300 cycles par séance) à quatre assemblages os bovin–Ti6Al4V sous une plaque commune. La charge était mesurée pour l’ensemble; les forces individuelles n’étaient pas mesurées.

Matériaux (2)

Matériau

Os

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.