Ligament et tendon (artificiel)
Ligaments and tendons can tear and rupture following an injury.
À propos de ce matériau
(En anglais seulement) Ligaments and tendons can tear and rupture following an injury. Repair is the first choice, but often a torn ligament or tendon heals poorly and must be replaced by artificial connective tissue or by a synthetic replicate. Determining mechanical properties of these artificial tissues is essential in the successful development of tissue-engineered constructs to mimic the native tissue.
Configurations de test (8)
Compression Non-Confinée
Indentation (Raideur)
Compression et Torsion simultanée
Analyse Mécanique Dynamique

Contrôle de la temperature
Capteurs analogues externes
Flux de caméra
Ressources associées (1)
Littérature associée
Near Infrared Spectroscopy Assessment of Achilles Tendon Biomechanical Properties
Itä-Suomen yliopisto, University of Eastern Finland, Pro gradu, Masters thesis, Published: 2025-07-03
Functional changes to Achilles tendon and enthesis in an adolescent mouse model of testosterone hormone therapy
LeeAnn A. Hold; Tessa Phillips; Paige Cordts; Stephanie S. Steltzer; Seung-Ho Bae; Brandon W. Henry; Nicole Migotsky; Sydney Grossman; Cynthia Dela Cruz; Vasantha Padmanabhan; Molly B. Moravek; Ariella Shikanov; Adam C. Abraham; Megan L. Killian
Connective Tissue Research, 66(2), 96–106. , Published: 28 Feb 2025
0 citations · 0 en 2025–2026
Unraveling the Metabolic Mosaic of Tendon Health and Disease
A dissertation submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy, University of Michigan, 2025
0 citations · 0 en 2025–2026
The human patellar tendon is mechanically homogenous at its mid-substance
Adam Kositsky; Lauri Stenroth; Ervin Nippolainen; Jari Torniainen; Janne T.A. Mäkelä; Petri Paakkari; Tommi Paakkonen; Heikki Kröger; Juha Töyräs; Isaac O. Afara; Rami K. Korhonen
Journal of the Mechanical Behavior of Biomedical Materials, Volume 163, ISSN 1751-6161, Published: 2025
3 citations · 3 en 2025–2026
Correlations between elastic modulus and ultrashort echo time (UTE) adiabatic T1P relaxation time (UTE-Adiab-T1P) in Achilles tendons and entheses
Saeed Jerban; Amir Masoud Afsahi; Yajun Ma; Dina Moazamian; Sheronda Statum; Alecio F. Lombardi; Lena Kakos; Erik Dorthe; Daryll Dlima; Jiang Du; Christine B. Chung; Eric Y. Chang
Journal of Biomechanics, Volume 160, 2023, 111825, ISSN 0021-9290, Published: November 2023
6 citations · 2 en 2025–2026
Adaptation of Fibril-Reinforced Poroviscoelastic Properties in Rabbit Collateral Ligaments 8 Weeks After Anterior Cruciate Ligament Transection
Gustavo A. Orozco; Aapo Ristaniemi; Mehrnoush Haghighatnejad; Ali Mohammadi; Mikko A. J. Finnilä; Simo Saarakkala; Walter Herzog; Hanna Isaksson; Rami K. Korhonen
Ann Biomed Eng (2022), Published: 21 September 2022
4 citations · 2 en 2025–2026
Change in viability of C2C12 myoblasts under compression, shear and oxidative challenges
Ye Hong; Yifei Yao; Singwan Wong; Liming Bian; Arthur F.T. Mak
Journal of biomechanics, 49(8), 1305-1310. (2016)
12 citations · 2 en 2025–2026
Electrospun poly(L-lactide-co-acryloyl carbonate) fiber scaffolds with a mechanically stable crimp structure for ligament tissue engineering
Fei Chen; James W. S. Hayami; Brian G. Amsden
Biomacromolecules. 2014;15(5):1593-1601.
71 citations · 6 en 2025–2026
Biomimetic poly(lactide) based fibrous scaffolds for ligament tissue engineering
Denver C. Surrao; Stephen D. Waldman; Brian G. Amsden
Acta Biomaterialia. 2012.
68 citations · 3 en 2025–2026
A crimp-like microarchitecture improves tissue production in fibrous ligament scaffolds in response to mechanical stimuli
Denver C. Surrao; Jackie C.Y. Fan; Stephen D. Waldman; Brian G. Amsden
Acta Biomaterialia. 2012.
55 citations · 8 en 2025–2026
Biomimetic scaffolds for ligament tissue engineering
Thesis, Queen’s University, 2011.
1 citation · 0 en 2025–2026
FAQ
Qu'est-ce que le module d'Young E?+
Module de laboratoire — Compression non confinée de disques d’hydrogel
Qu'est-ce que l'allongement à la rupture?+
Comment fonctionne le modèle "Sinusoid"? +
(En anglais seulement) This feature is used to obtain the Frequency, Amplitude and Offset of a sinusoidal signal. A blue line displays the theoretical sinusoid with the Frequency, Amplitude and Offset obtained (Figure 1). The values of the Frequency, Amplitude and Offset are indicated in the "Results" field. The units vary according to the graph’s axes.
This feature can also be used for sinusoidal stimulus-response analysis. Sinusoidal stimulus shall be selected on the x-axis and the sinusoidal response on the y-axis. The Modulus is the ratio of the response Amplitude over the stimulus Amplitude. The Phase is the phase difference between the response and the stimulus. The Modulus’ is computed as the Modulus*Cos(Phase) and the Modulus” is computed as the Modulus*Sin(Phase). A blue line displays the theoretical sinusoidal stimulus-response with the Frequency, Modulus and Phase obtained (Figure 2). The values of the Modulus and Phase are indicated in the “Results” field. The units vary according to the graph’s axes.
One use for this feature would be to compute material properties by multiplying the Modulus obtained by the appropriate geometric factors. For example, the Young’s Modulus can be obtained during uniaxial compression or tension on cylindrical sample with t/pi*r2 as the geometric factor, t is the thickness and r is the radius of the sample.
Mach-1 Analysis – Sinusoid – Exemple d’analyse stimulus-réponse
Comment fonctionne la fonction Creep (Fluage)?+
Qu'est-ce que la résistance ultime à la traction (résistance à la traction)?+
Qu'est-ce que la limite élastique de la rigidité?+
Qu'est-ce que l'élasticité?+
Module de laboratoire — Torsion de l’os
LAB MODULE – Unconfined Compression of Hydrogel Disks – Student Version
