Aller au contenu

High Impact Exercise Improves Bone Microstructure and Strength in Growing Rats

  • par garon@biomomentum.com

Tanvir Mustafy; Irène Londono; Florina Moldovan; Isabelle Villemure
Nature Scientific Reports, volume 9, Article number: 13128 (2019)

https://doi.org/10.1038/s41598-019-49432-2

36 citations · 11 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Physical activity is beneficial for skeletal development. However, impact sports during adolescence, leading to bone growth retardation and/or bone quality improvement, remains unexplained. This study investigated the effects of in vivo low (LI), medium (MI), and high (HI) impact loadings applied during puberty on bone growth, morphometry and biomechanics using a rat model. 4-week old rats (n=30) were divided into control, sham, LI, MI, and HI groups. The impact was applied on the right tibiae, 5 days/week for 8 weeks mimicking walking (450 µe), uphill running (850 µe) and jumping (1250 µe) conditions. Trabecular and cortical parameters were determined by micro-CT, bone growth rate by calcein labeling and toluidine blue staining followed by histomorphometry. Bio-mechanical properties were evaluated from bending tests. HI group reduced rat body weight and food consumption compared to shams. Bone growth rate also decreased in MI and HI groups despite developing thicker hypertrophic and proliferative zone heights. HI group showed significant increment in bone mineral density, trabecular thickness, cortical and total surface area. Ultimate load and stiffness were also increased in MI and HI groups. We conclude that impact loading during adolescence reduces bone growth moderately but improves bone quality and biomechanics at the end of the growing period.

Utilisation des équipements

Un système Mach-1 contrôlait un dispositif personnalisé appliquant un chargement axial cyclique aux tibias de rats in vivo.

Figures

Table comparing structural and intrinsic mechanical properties of rat tibiae across loading groups.
Figure 1 — Show caption

ANOVA test with Tukey’s multiple comparisons for structural and intrinsic mechanical properties of the right tibiae from control, sham, LI, MI and HI groups of rats derived from three-point bending tests of the mid-diaphysis. Values are expressed as Mean ± SD, N = 6/group. In the parameter column, * indicates a significant effect (p < 0.05) from a one-way ANOVA with Tukey’s multiple comparisons test. When there was a significant effect, Tukey’s post-hoc pairwise comparisons evaluated whether the sham group was significantly different compared to the other groups [a bold value and α indicate a significant difference versus sham group].

T. Mustafy. I. Londono, F. Moldovan and I. Villemure — Table 3

Figure source

Rat tibial loading apparatus, cyclic waveform and strain gauge calibration.
Figure 2 — Show caption

Impact loading setup and strain gauge calibration. (A) With the rats under anesthesia, the right tibiae from LI, MI and HI groups were loaded using a waveform generating 450, 850, and 1250 με at the medio-proximal tibial surface from the 4 to 11 week period. (B) The loading profile consisted of haversine waveform displacements at 2 Hz and characterized by symmetric loading/unloading with a 0.10 sec of rest insertion between loading cycles. Loadings were repeated for 1200 cycles, yielding a daily (5 days/week) loading period of 10 minutes. (C) Strain gauge positioned at the medio-proximal surface of the tibia for allowing strain assessment for 0.5 mm to 3.5 mm of displacement. (D) Linear relationship between applied displacement and resulting strain at the medio-proximal surface of 4, 8 and 12 week old rat tibiae (mean value ± SD) (N = 6 rats/group).

T. Mustafy. I. Londono, F. Moldovan and I. Villemure — Figure 4

Figure source

Tibial micro-CT volumes of interest and three-point bending test configuration.
Figure 3 — Show caption

Trabecular and cortical volume of interests and experimental setup for three-point bending tests. (A) Representative 3D reconstructed tibia showing the total tibial length (L). The trabecular VOI started at ~0.35 mm distal to the growth plate and extended for 12% of the overall bone length (L). The VOI for cortical bone was centered at the tibial mid-diaphysis and extended proximally and distally for 5% of the tibial length (L). Volumes of interest including only trabecular and cortical bone were semi-automatically segmented using an in-house algorithm. (B) I-Experimental setup for the three-point bending tests. A distance of 50% of the total tibial length was fixed between the supports, while the remaining 50% was distributed equally between the external sides of the supports. II-Representative image of the fractured tibia after the bending test.

T. Mustafy. I. Londono, F. Moldovan and I. Villemure — Figure 5

Figure source

Matériaux (2)

Matériau

Os

Configurations de test (3)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.