Aller au contenu

The shear mechanical properties of diabetic and non-diabetic plantar soft tissue

  • par garon@biomomentum.com

Shruti Pai; William R. Ledoux
Journal of biomechanics, 45(2), 364-370. (2012)

https://doi.org/10.1016/j.jbiomech.2011.10.021

64 citations · 5 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Changes in the plantar soft tissue shear properties may contribute to ulceration in diabetic patients, however, little is known about these shear parameters. This study examines the elastic and viscoelastic shear behavior of both diabetic and non-diabetic plantar tissue. Previously compression tested plantar tissue specimens (n = 54) at six relevant plantar locations (hallux, first, third, and fifth metatarsal heads, lateral midfoot, and calcaneus) from four cadaveric diabetic feet and five non-diabetic feet were utilized. Per in vivo data (i.e., combined deformation patterns of compression followed by shear), an initial static compressive strain (36–38%) was applied to the tissue followed by target shear strains of 50% and 85% of initial thickness. Triangle waves were used to quantify elastic parameters at both strain levels and a stress relaxation test (0.25s ramp and 300s hold) was used to quantify the viscoelastic parameters at the upper strain level. Several differences were found between test groups including a 52–62% increase in peak shear stress, a 63% increase in toe shear modulus, a 47% increase in final shear modulus, and a 67% increase in middle slope magnitude (sharper drop in relaxation) in the diabetic tissue. Beyond a 54% greater peak compressive stress in the third metatarsal compared to the lateral midfoot, there were no differences in shear properties between plantar locations. Notably, this study demonstrates that plantar soft tissue with diabetes is stiffer than healthy tissue, thereby compromising its ability to dissipate shear stresses borne by the foot that may increase ulceration risk.
Keywords: foot; diabetes; subcutaneous; ulceration; viscoelastic

Utilisation des équipements

Le Mach-1 mesurait la réponse au cisaillement de tissus mous plantaires soumis à une charge compressive statique.

Article et documents

Matériaux (1)

Configurations de test (2)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.