Abstract

In this study, we observe that the poromechanical parameters in human meniscus vary spatially throughout the tissue. The response is anisotropic and the porosity is functionally graded. To draw these conclusions, we measured the anisotropic permeability and the “aggregate modulus” of the tissue, i.e., the stiffness of the material at equilibrium, after the interstitial fluid has ceased flowing. We estimated those parameters within the central portion of the meniscus in three directions (i.e., vertical, radial and circumferential) by fitting an enhanced model on stress relation confined compression tests. We noticed that a classical biphasic model was not sufficient to reproduce the observed experimental behaviour. We propose a poroelastic model based on the assumption that the fluid flow inside the human meniscus is described by a fractional porous medium equation analogous to Darcy’s law, which involves fractional operators. The fluid flux is then time-dependent for a constant applied pressure gradient (in contrast with the classical Darcy’s law, which describes a time independent fluid flux relation). We show that a fractional poroelastic model is well-suited to describe the flow within the meniscus and to identify the associated parameters (i.e., the order of the time derivative and the permeability).

Keywords 

Poromechanics experiments; confined compression test; human meniscus; fractional darcy; constitutive model

Utilisation des équipements

La section de méthode mentionne un appareil Mach-1 et décrit des essais de compression.

Les détails du protocole sont conservés en anglais dans cette rubrique; consulter la publication originale pour le contexte expérimental complet.

Figures

Confined compression chamber for a meniscus specimen and schematic boundary conditions.
Figure 1 — Show caption

(a) The confined compression test set up. Cylindrical specimens are extracted from a human meniscus. (b) The cylinder is then confined inside a glass chamber with a porous base and compressed by a metal bar. During compression, the water in the meniscal sample flows from the base of the cylinder. (b) Schematic representation of the boundary conditions used to solve the boundary value problem.

Raphael Bulle, Gioacchino Alotta, Gregorio Marchiori, Matteo Berni, Nicola F. Lopomo, Stefano Zaffagnini, Stephane P. A. Bordas & Olga Barrera — Figure 2

Figure source

Article et documents

Matériaux (1)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.