Aller au contenu

Stress State and Strain Rate Dependence of the Human Placenta

  • par garon@biomomentum.com

Benjamin C. Weed; Ali Borazjani; Sourav S. Patnaik; R. Prabhu; M. F. Horstemeyer; Peter L. Ryan; Thomas Franz; Lakiesha N. Williams; Jun Liao
Annals of Biomedical Engineering. 2012.

https://doi.org/10.1007/s10439-012-0588-2

16 citations · 1 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Maternal trauma (MT) in automotive collisions is a source of injury, morbidity, and mortality for both mothers and fetuses. The primary associated pathology is placental abruption in which the placenta detaches from the uterus leading to hemorrhaging and termination of pregnancy. In this study, we focused on the differences in placental tissue response to different stress states (tension, compression, and shear) and different strain rates. Human placentas were obtained (n = 11) for mechanical testing and microstructure analysis. Specimens (n = 4+) were tested in compression, tension, and shear, each at three strain rates (nine testing protocols). Microstructure analysis included scanning electron microscopy, histology, and interrupted mechanical tests to observe tissue response to various loading states. Our data showed the greatest stiffness in tension, followed by compression, and then by shear. The study concludes that mechanical behavior of human placenta tissue (i) has a strong stress state dependence and (ii) behaves in a rate dependent manner in all three stress states, which had previously only been shown in tension. Interrupted mechanical tests revealed differences in the morphological microstructure evolution that was driven by the kinematic constraints from the different loading states. Furthermore, these structure-property data can be used to develop high fidelity constitutive models for MT simulations.

Utilisation des équipements

Un Mach-1 évaluait du placenta humain frais en traction, compression non confinée et cisaillement, à plusieurs vitesses de déformation. Chaque mode utilisait une géométrie et un montage distincts.

Matériaux (1)

Configurations de test (3)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.