Objective

The objective of this study was to assess a novel 3D microstructured scaffold seeded with allogeneic chondrocytes (cells) in a rabbit osteochondral defect model.

Design

Direct laser writing lithography in pre-polymers was employed to fabricate custom silicon-zirconium containing hybridorganic-inorganic (HOI) polymer SZ2080 scaffolds of a predefined morphology. Hexagon-pored HOI scaffolds were seeded with chondrocytes (cells), and tissue-engineered cartilage biocompatibility, potency, efficacy and shelf-life in vitro was assessed by morphological, ELISA (enzyme-linked immunosorbentassay) and PCR (polymerase chain reaction) analysis. Osteochondral defect was created in the weight-bearing area of medial femoral condyle for in vivo study. Polymerized fibrin was added to every defect of 5 experimental groups. Cartilage repair was analyzed after 6 months using macroscopical (Oswestry Arthroscopy Score [OAS]), histological, and electromechanical quantitative potential (QP) scores. Collagen scaffold (CS) was used as a positive comparator for in vitro and in vivo studies.

Results

Type II collagen gene up regulation and protein secretion was maintained up to 8 days in seeded HOI. In vivo analysis revealed improvement in all scaffold treatment groups. For the first time, electromechanical properties of a cellular-based scaffold were analyzed in a preclinical study. Cell addition did not enhance OAS but improved histological and QP scores in HOI groups.

Conclusions

HOI material is biocompatible for up to 8 days in vitro and is supportive of cartilage formation at 6 months in vivo. Electromechanical measurement offers a reliable quality assessment of repaired cartilage.

Utilisation des équipements

Arthro-BST a évalué les propriétés électromécaniques du cartilage de réparation six mois après implantation dans un modèle de défaut ostéochondral chez le lapin étudiant des échafaudages microstructurés. Les mesures de QP ont été réalisées sur les défauts traités et sur du cartilage sain de la zone portante du condyle fémoral latéral. L’appareil évaluait le tissu réparé, et non les propriétés mécaniques du matériau d’échafaudage isolé.

Matériaux (3)

Configurations de test (1)

Produits (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.