Aller au contenu

Optimising the decellularization of human elastic cartilage with trypsin for future use in ear reconstruction

  • par garon@biomomentum.com

Shafiq Rahman; Michelle Griffin; Anish Naik; Matthew Szarko; Peter E. M. Butler
Scientific Reports (2018) 8:3097

https://doi.org/10.1038/s41598-018-20592-x

82 citations · 16 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Decellularized scaffolds can induce chondrogenic differentiation of stem cells. This study compares different methods to optimise the decellularization of auricular cartilage. The process consisted of an initial 12 hour dry freeze thaw which froze the cartilage specimens in an empty tube at −20 °C. Samples were allowed to thaw at room temperature followed by submersion in phosphate buffer solution in which they were frozen at −20 °C for a 12 hour period. They were then allowed to thaw at room temperature as before. Protocol A subsequently involved subjecting specimens to both deoxyribonuclease and sodium deoxycholate. Protocol B and C were adaptations of this using 0.25% trypsin (7 cycles) and a 0.5 molar solution of ethylenediaminetetraacetic acid (3 hours for each cycle) respectively as additional steps. Trypsin accelerated the decellularization process with a reduction in DNA content from 55.4 ng/uL (native) to 17.3 ng/uL (P-value < 0.05) after 14 days. Protocol B showed a faster reduction in DNA content when compared with protocol A. In comparison to protocol C after 14 days, trypsin also showed greater decellularization with a mean difference of 11.7 ng/uL (P-value < 0.05). Histological analysis with H&E and DAPI confirmed depletion of cells at 14 days with trypsin.

Utilisation des équipements

Le Mach-1 Mechanical Tester a servi à réaliser des essais de compression par indentation sur des échantillons de cartilage auriculaire afin d’évaluer leurs propriétés mécaniques après différents protocoles de décellularisation. Le module de Young était rapporté pour le cartilage natif et à la fin de chacun des trois protocoles, permettant une comparaison mécanique complémentaire aux analyses tissulaires.

Matériaux (1)

Configurations de test (1)

Produits (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.