Mechanical loading of ex vivo bovine trabecular bone in 3D printed bioreactor chambers

  • par garon@biomomentum.com

Brian A. Kunath; Kail Beloglowka; Roshni Rainbow; Heidi-Lynn Ploeg
Journal of the Mechanical Behavior of Biomedical Materials 153 (2024), 106470. Original abstract: English.

https://doi.org/10.1016/j.jmbbm.2024.106470

5 citations · 4 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Previous ex vivo bone culture methods have successfully implemented polycarbonate (PC) bioreactors to investigate bone adaptation to mechanical load; however, they are difficult to fabricate and have been limited to a 5 mm maximum specimen height. The objective of this study was to validate a custom-made 3D printed MED610TM bioreactor system that addresses the limitations of the PC bioreactor and assess its efficacy in ex vivo bone culture. Twenty-three viable trabecular bone cores (10 mm height by 10 mm diameter) from an 18-month-old bovine sternum were cultured in MED610TM bioreactors with culture medium at 37 °C and 5% CO2 for 21-days. Bone cores were ranked based on their day 0 apparent elastic modulus (Eapp) and evenly separated into a « Load » group (n = 12) and a control group (n = 11). The Load group was loaded five times per week with a sinusoidal strain waveform between -1000 and -5000 με for 120 cycles at 2 Hz. Eapp was assessed on day 0, 8, and 21 using quasi-static tests with a -4000 με applied strain. Over 21-days, the Eapp of Load group samples tended to increase by more than double the control group (53.4% versus 20.9%) and no visual culture contamination was observed. This study demonstrated that bone organ culture in 3D printed MED610TM bioreactors replicated Eapp trends found in previous studies with PC bioreactors. However, further studies are warranted with a larger sample size to increase statistical power and histology to assess cell viability and bone mineral apposition rate.

Utilisation des équipements

Un Mach-1 équipé d’une cellule multiaxiale de 250 N comprimait des carottes d’os trabéculaire bovin dans des bioréacteurs MED610 avec un montage lubrifié à rotule. Les essais quasi statiques mesuraient le module apparent; la stimulation comportait 120 cycles à 2 Hz, cinq jours par semaine. Le chargement était effectué à température ambiante.

Matériaux (1)

Matériau

Os

Configurations de test (2)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.