Aller au contenu

Injectable Dynamically Crosslinked Zwitterionic Hydrogels as a Viscosupplement for Osteoarthritis Treatment

  • par garon@biomomentum.com

Nahieli Preciado Rivera; Mara Jenkins; Duy Anh Pham; Norma A. Garza Flores; Christina McCabe; Anuj Saini; Gurpreet K. Randhawa; Mandana Tavakolian; Saanvi Sood; Mackenzie Belchos; Isabella Jun; Xavier Banquy; Todd Hoare
ACS Applied Materials & Interfaces. 2026;18(37):50647–50662. First published 15 September 2026.

https://doi.org/10.1021/acsami.6c15705

0 citations · 0 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

While hyaluronic acid-based viscosupplements have been widely used clinically for osteoarthritis treatment, their rapid in vivo degradation and variable biological interactions have led to inconsistent patient outcomes. Herein, we report the use of a dynamically crosslinked hydrazone-based zwitterionic hydrogel based on mixing hydrazide (ZH) and aldehyde (ZA) or ketone (ZK)-functionalized precursor polymers as an alternative to hyaluronic acid-based viscosupplements. Upon coinjection via a double-barrel syringe, the water-like precursor polymer solutions gel within ∼0.5-3 min. Relative to a leading hyaluronic acid-based product (Synvisc®), the dynamic zwitterionic hydrogels showed 10-50× higher compressive moduli, beneficial to mechanically support the joint while at the same time exhibiting a 5-9× higher reduction in the coefficient of friction at walking frequencies against an alumina surface over 400 cycles and a >25% lower coefficient of friction against ex vivo cartilage samples, all while also being easy to inject given the low initial viscosity of the precursor polymers. The hydrogel was noncytotoxic and showed minimal inflammatory responses when injected in vivo, with the ZA formulations persisting for >90 days postinjection compared to only days for conventional HA-based viscosupplements. Overall, zwitterionic dynamic hydrogels provide a combination of mechanical support, lubricity, and in vivo inertness/stability while being injectable, suggesting promise for clinical translation for osteoarthritis treatment.

Utilisation des équipements

La description des informations supplémentaires de l’éditeur identifie un montage de compression cyclique Mach-1 avec un support de plaque à 96 puits imprimé en 3D et des courbes contrainte–déformation des hydrogels. Elle étaye des essais de compression des hydrogels zwitterioniques pour caractériser leur soutien mécanique; le protocole complet et le confinement latéral restent inconnus.

Matériaux (1)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.