Skip to content

Injectable Dynamically Crosslinked Zwitterionic Hydrogels as a Viscosupplement for Osteoarthritis Treatment

  • by garon@biomomentum.com

Nahieli Preciado Rivera; Mara Jenkins; Duy Anh Pham; Norma A. Garza Flores; Christina McCabe; Anuj Saini; Gurpreet K. Randhawa; Mandana Tavakolian; Saanvi Sood; Mackenzie Belchos; Isabella Jun; Xavier Banquy; Todd Hoare
ACS Applied Materials & Interfaces. 2026;18(37):50647–50662. First published 15 September 2026.

https://doi.org/10.1021/acsami.6c15705

0 citations · 0 in 2025–2026

While hyaluronic acid-based viscosupplements have been widely used clinically for osteoarthritis treatment, their rapid in vivo degradation and variable biological interactions have led to inconsistent patient outcomes. Herein, we report the use of a dynamically crosslinked hydrazone-based zwitterionic hydrogel based on mixing hydrazide (ZH) and aldehyde (ZA) or ketone (ZK)-functionalized precursor polymers as an alternative to hyaluronic acid-based viscosupplements. Upon coinjection via a double-barrel syringe, the water-like precursor polymer solutions gel within ∼0.5-3 min. Relative to a leading hyaluronic acid-based product (Synvisc®), the dynamic zwitterionic hydrogels showed 10-50× higher compressive moduli, beneficial to mechanically support the joint while at the same time exhibiting a 5-9× higher reduction in the coefficient of friction at walking frequencies against an alumina surface over 400 cycles and a >25% lower coefficient of friction against ex vivo cartilage samples, all while also being easy to inject given the low initial viscosity of the precursor polymers. The hydrogel was noncytotoxic and showed minimal inflammatory responses when injected in vivo, with the ZA formulations persisting for >90 days postinjection compared to only days for conventional HA-based viscosupplements. Overall, zwitterionic dynamic hydrogels provide a combination of mechanical support, lubricity, and in vivo inertness/stability while being injectable, suggesting promise for clinical translation for osteoarthritis treatment.

Equipment used

The publisher’s Supporting Information description identifies a Mach-1 cyclical compression setup with a 3D-printed 96-well plate holder and reports hydrogel compression stress–strain curves. This supports Mach-1 compression testing of zwitterionic hydrogels to characterize mechanical support; the full protocol and lateral confinement conditions are unavailable.

Materials (1)

Test configurations (1)

See Research in Action

Explore case studies

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.