Mechanical loading of articular cartilage can produce catabolic and anabolic changes in tissue metabolism. Most previous studies in this area have focussed on aggrecan. Little information concerning load-induced collagen modifications has been obtained. We have therefore conducted studies where mechanical loads are applied in vitro to full thickness cartilage explants retaining a thin layer of bone, in order to investigate mechanically induced collagen breakdown and consequent turnover, in addition to aggrecan changes and mechanical property alterations. Tissue explant disks were subjected to unconfined compression and either immediately frozen or kept in static culture for 10 days. Mechanical tests of the disks immediately prior to and just after the cyclic loading period were also performed. They showed a weakening of the collagen network and an increased hydraulic permeability due to the cyclic loading. Load-induced alterations of the extracellular matrix was then clearly evidenced by an increase in denatured collagen in the disks frozen immediately after loading compared to unloaded controls. Loaded disks maintained in culture for 10 additional days following cyclic loading no longer expressed this increase in denatured collagen suggesting that mechanically denatured collagen II had undergone a removal process which could represent turnover or repair, or the beginning of progressive degradation. Indeed matrix fragments of collagen II and glycosaminoglycans were found to be released to post-loading culture medium in increased quantities compared to unloaded controls. Our data further demonstrates the ability of mechanical load of articular cartilage to modulate turnover and metabolism of collagen and proteoglycan in a complex and multifactorial manner that may be of particular significance in the pathogenesis of osteoarthritis and in the development of pharmacological agents to modulate its progression.

Utilisation des équipements

Un Mach-1 (Biosyntech) appliquait une compression cyclique non confinée à des explants de cartilage bovin conservant une mince couche osseuse. Des essais de relaxation avant et après chargement évaluaient la perméabilité hydraulique et les modules matriciel et fibrillaire, pour étudier les dommages au collagène et le renouvellement de la matrice.

Article et documents

Matériaux (1)

Configurations de test (3)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.