Aller au contenu

Biomechanical properties and microstructure of neonatal porcine ventricles

  • par garon@biomomentum.com

Faizan Ahmad; Raj. Prabhu; Jun Liao; Shwe Soe; Michael D. Jones; Jonathan Miller; Parker Berthelson; Daniel Enge; Katherine M. Copeland; Samar Shaabeth; Richard Johnston; Ian Maconochie; Peter S. Theobald
Journal of the Mechanical Behavior of Biomedical Materials 88 (2018), 18–28. Accepted manuscript deposited in Swansea University Cronfa; original English abstract copied from manuscript PDF page 4. Specimen: native neonatal porcine ventricular myocardium, represented by Custom Material because the current Heart (Tissue Engineering) category would be misleading. Biaxial extension used a separate system.

https://doi.org/10.1016/j.jmbbm.2018.07.038

27 citations · 7 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Neonatal heart disorders represent a major clinical challenge, with congenital heart disease alone affecting 36,000 new-borns annually within the European Union. Surgical intervention to restore normal function includes the implantation of synthetic and biological materials; however, a lack of experimental data describing the mechanical behaviour of neonatal cardiac tissue is likely to contribute to the relatively poor short- and long-term outcome of these implants. This study focused on characterising the mechanical behaviour of neonatal cardiac tissue using a porcine model, to enhance the understanding of how this differs to the equivalent mature tissue. The biomechanical properties of neonatal porcine cardiac tissue were characterised by uniaxial tensile, biaxial tensile, and simple shear loading modes, using samples collected from the anterior and posterior walls of the right and left ventricles. Histological images were prepared using Masson’s trichrome staining, to enable assessment of the microstructure and correlation with tissue behaviour. The mechanical tests demonstrated that the neonatal cardiac tissue is non–linear, anisotropic, viscoelastic and heterogeneous. Our data provide a baseline describing the biomechanical behaviour of immature porcine cardiac tissue. Comparison with published data also indicated that the neonatal porcine cardiac tissue exhibits one-half the stiffness of mature porcine tissue in uniaxial extension testing, one-third in biaxial extension testing, and one-fourth stiffness in simple shear testing; hence, it provides an indication as to the relative change in characteristics associated with tissue maturation. These data may prove valuable to researchers investigating neonatal cardiac mechanics.

Utilisation des équipements

Un Mach-1 testait le myocarde ventriculaire natif de porcelets nouveau-nés en traction uniaxiale et en cisaillement simple. Les éprouvettes de traction étaient préconditionnées puis étirées jusqu’à rupture; le cisaillement utilisait des plaques spécifiques dans du PBS à 37 °C. La traction biaxiale utilisait un appareil distinct.

Matériaux (1)

Configurations de test (2)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.