Aller au contenu

Augmentation and vocal fold biomechanics in a recurrent laryngeal nerve injury model

  • par garon@biomomentum.com

Solaleh Miar; Benjamin Walters; Gabriela Gonzales; Ronit Malka; Amelia Baker; Teja Guda; Gregory R. Dion
Wiley Online Library, Original Research, Published: 06 July 2022

https://doi.org/10.1002/lio2.853

7 citations · 0 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract

Objectives/hypothesis:

Composite vocal fold (VF) biomechanical data are lacking for augmentation after recurrent laryngeal nerve (RLN) injury. We hypothesize resulting

atrophy decreases VF stiffness and augmentation restores native VF biomechanics.

Methods:

Sixteen Yorkshire Crossbreed swine underwent left RLN transection and were observed or underwent carboxymethylcellulose (CMC) or calcium hydroxyapatite (CaHa) augmentation at 2 weeks. Biomechanical measurements (structural stiffness, displacement, and maximum load) were measured at 4 or 12 weeks. Thyroarytenoid (TA) muscle cross-sectional area was quantified and compared with two-way ANOVA with Tukey's

post hoc test.

Results:

After 4 weeks, right greater than left structural stiffness (mean ± SE) was observed (49.6 ± 0.003 vs. 28.4 ± 0.002 mN/mm), left greater than right displacement at 6.3 mN (0.54 ± 0.01 vs. 0.46 ± 0.01 mm, p < .01) was identified, and right greater than left maximum load (72.3 ± 0.005 vs. 40.8 ± 0.003 mN) was recorded. TA muscle atrophy in the injured group without augmentations was significant compared to the noninjured side, and muscle atrophy was seen at overall muscle area and individual muscle bundles. CMC augmentation appears to maintain TA muscle structure in the first 4 weeks with atrophy present at 12 weeks.

Conclusions:

VF biomechanical properties match TA muscle atrophy in this model, and both CMC and CaHa injection demonstrated improved biomechanical properties and slower TA atrophy compared to the uninjured side. Taken together, these data provide a quantifiable biomechanical basis for early injection laryngoplasty to improve dysphonia and potentially improve healing in reversible unilateral vocal fold atrophy.

Keywords

Augmentation, Biomechanics, Muscle atrophy, Recurrent laryngeal nerve injury, Swine

Utilisation des équipements

Le Mach-1 Mechanical Tester a évalué la mécanique des plis vocaux dans un modèle porcin de lésion du nerf laryngé récurrent avec augmentation. L’indentation sphérique aux points définis par un gabarit mesurait la rigidité structurale, le déplacement à une force donnée et la charge maximale. Le montage utilisait un capteur de force uniaxial; les échantillons étaient fixés dans un moule en plâtre et immergés dans une solution saline tamponnée au phosphate.

Article et documents

Matériaux (2)

Configurations de test (3)

Découvrez la recherche en pratique