Aller au contenu

Activation of connexin hemichannels enhances mechanosensitivity and anabolism in disused and aged bone

  • par garon@biomomentum.com

Dezhi Zhao; Chao Tu; Lidan Zhang; Teja Guda; Sumin Gu; Jean X. Jiang
JCI Insight, PMID: 39641271; PMCID: PMC11623949, Published: 6 Dec 2024

https://doi.org/10.1172/jci.insight.177557

12 citations · 12 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract:

Mechanical loading, essential for bone health, promotes bone formation and remodeling. However, the positive response diminishes in cases of disuse and aging, leading to bone loss and an increased fracture risk. This study demonstrates that activating hemichannels (HCs) using a connexin 43 (Cx43) antibody, Cx43(M2), in bone osteocytes revitalizes aging and disused bones. Using a hindlimb suspension (HLS) disuse model and a tibial mechanical loading model, we found that Cx43(M2) inhibited bone loss and osteocyte apoptosis induced by unloading in 16-week-old adult mice. Additionally, it enhanced bone mass in response to tibial loading in 22-month-old aged mice. The HC opening released bone anabolic factor prostaglandin E2 (PGE2) and suppressed catabolic factor sclerostin (SOST). This suppressed the increase of cortical bone formation and reduction of bone resorption during unloading and promoted trabecular and cortical bone formation during loading. Cx43(M2)-induced HC opening, coupled with PGE2 release, effectively rescued unloading-induced bone loss and restored the diminished anabolic response of aged bones to mechanical loading. Activating HCs with the Cx43 antibody holds promise as a de novo therapeutic approach, as it can overcome the limitations of existing treatment regimens for treating bone loss and osteoporosis associated with aging and disuse.

Keywords:

Bone biology, Bone disease, Drug therapy.

Utilisation des équipements

La section de méthode mentionne un appareil Mach-1 et décrit des essais de flexion.

Les détails du protocole sont conservés en anglais dans cette rubrique; consulter la publication originale pour le contexte expérimental complet.

Article et documents

Matériaux (1)

Matériau

Os

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.