Aller au contenu

A rheological approach to assess the printability of thermosensitive chitosan-based biomaterial inks

  • par garon@biomomentum.com

Maedeh Rahimnejad; Thierry Labonté-Dupuis; Nicole R Demarquette; Sophie Lerouge
Biomedical Materials, Accepted Manuscript online 26 August 2020 • © 2020 IOP Publishing Ltd

https://doi.org/10.1088/1748-605x/abb2d8

46 citations · 19 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

For extrusion-based bioprinting, the inks must be printable and rapidly present sufficient mechanical properties to support additional layers and provide a cohesive, manipulable structure. Thermosensitive hydrogels may therefore be interesting candidates. However, the use of these materials is particularly challenging since their rheological properties evolve with time and temperature. In this work, a rheological approach to characterize the printability of chitosan-based thermosensitive inks was developed. The method consists of evaluating:1) the gelation kinetic at room temperature and 37C; 2) shear thinning behavior to estimate the shear rate applied during printing as a function of printing parameters ; 3) the viscosity after shear removal (recovery test) to simulate behaviour after biomaterial deposition. Hydrogels containing 2 and 3%w/vol chitosan, combined with different gelling agents (Sodium-hydrogen-carbonate (SHC), Phosphate-buffer, Beta-glycerophosphate (BGP)) were tested, and compared with alginate/Gelatin bioink as controls. To correlate the rheological studies with real printing conditions, 3D-Discovery bioprinter was used to print hydrogels and the visual aspect of the printed structure was observed. Unconfined compressive tests were carried out to study the impact of applied shear rate during printing on the mechanical properties of printed structures. All pre-hydrogel solutions presented shear thinning properties. The recovery of viscosity was found to depend on the hydrogel formulation, as well as the level of shear rate and the state of gelation at the time of printing. Formulations made with SHC and phosphate buffer presented too rapid gelation and phase separation,leading to poor printing results. One particularly promising formulation composed of SHC and BGP, when printed at a shear rate of 140s-1, before its gelation time (tg≤15min), resulted in good printability and 3D structures with rigidity comparable with the Alginate/Gelatin bioink. The methodology introduced in this paper could be used to evaluate the printability of other time- and temperature dependent biomaterial inks in the future.
Post-printed mechanical properties Unconfined compression tests were performed on 5-layer printed honeycomb structures using the MACH-1 testing device (Biomomentum, Canada).

Utilisation des équipements

Le Mach-1 réalisait des essais de compression non confinée de structures en nid d’abeilles imprimées à base de chitosane.

Article et documents

Matériaux (2)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.