Aller au contenu

A novel palpation–based method for tumor nodule quantification in soft tissue—computational framework and experimental validation

  • par garon@biomomentum.com

Javier Palacio-Torralba; Robert L. Reuben; Yuhang Chen
Medical & Biological Engineering & Computing. 2020;58(6):1369–1381.

https://doi.org/10.1007/s11517-020-02168-y

18 citations · 2 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract
Variation in mechanical properties is a useful marker for cancer in soft tissue and has been used in clinical diagnosis for centuries. However, to develop such methods as instrumented palpation, there remain challenges in using the mechanical response during palpation to quantify tumor load. This study proposes a computational framework of identification and quantification of cancerous nodules in soft tissue without a priori knowledge of its geometry, size, and depth. The methodology, using prostate tissue as an exemplar, is based on instrumented palpation performed at positions with various indentation depths over the surface of the relevant structure (in this case, the prostate gland). The profile of force feedback results is then compared with the benchmark in silico models to estimate the size and depth of the cancerous nodule. The methodology is first demonstrated using computational models and then validated using tissue-mimicking gelatin phantoms, where the depth and volume of the tumor nodule is estimated with good accuracy. The proposed framework is capable of quantifying a tumor nodule in soft tissue without a priori information about its geometry, thus presenting great promise in clinical palpation diagnosis for a wide variety of solid tumors including breast and prostate cancer.
The tissue phantom was subjected to point-by-point indentation measurements over its top surface, using indentation test machine, Mach-1 V500css(Biomomentum Inc., Laval, Canada).
Keywords: Tissue mechanics. Quantitative diagnosis. Prostate cancer. Tumor detection

Utilisation des équipements

Le Mach-1 réalisait des indentations point par point d’un fantôme de tissu en gélatine contenant un nodule simulé.

Article et documents

Matériaux (2)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.