Tatiana S. Demina; Anastasia S. Kuryanova; Polina Y. Bikmulina; Nadejda A. Aksenova; Yuri M. Efremov; Zulfar I. Khaibullin; Pavel L. Ivanov; Nastasia V. Kosheleva; Peter S. Timashev; Tatiana A. Akopova
Polymers (Basel). 2020;12(9):E1911. Published 2020 Aug 25.
https://doi.org/10.3390/polym12091911
8 citations · 1 in 2025–2026
Abstract
The mimicking of the architectonics of native tissue, biodegradable non-woven fibrous mats is one of the most promising forms of scaffolding for tissue engineering. The key properties needed for their successful application in vivo, such as biodegradability, biocompatibility, morphology, mechanical properties, etc., rely on their composition and appropriate 3D structure. A multicomponent system based on biodegradable synthetic (polycaprolactone, oligo-/polylactide) and natural (chitosan, gelatin) polymers, providing the desired processing characteristics and functionality to non-woven mats fabricated via the electrospinning technique, was developed. The solid-state reactive blending of these components provided a one-step synthesis of amphiphilic graft copolymer with an ability to form stable ultra-fine dispersions in chlorinated solvents, which could be successfully used as casting solvents for the electrospinning technique. The synthesized graft copolymer was analyzed with the aim of fractional analysis, dynamic laser scattering, FTIR-spectroscopy and DSC. Casting solution characteristics, namely viscosity, surface tension, and electroconductivity, as well as electrospinning parameters, were studied and optimized. The morphology, chemical structure of the surface layer, mechanical properties and cytocompatibility were analyzed to confirm the appropriate functionality of the formed fibrous materials as scaffolds for tissue engineering.
Keywords: chitosan; cytocompatibility; electrospinning; gelatin; non-woven mats; polyesters; solvent-free co-extrusion.
Equipment used
Mechanical Testing
The mechanical properties of the PLA and PPCOG non-woven mat samples were tested in dry and wet states using Mach-1 v500csst Micromechanical Testing System (Biomomentum Inc., Laval, QC, Canada). The testing of the samples in wet mode was realized after their incubation in mQ water for 2
days during constant lateral stirring at 200–300 rpm at RT. The tensile strength, elongation at break and modulus of elasticity (Young’s modulus) were measured during the uniaxial tension of at least three dog bone-shaped samples (15 5 mm gauge) and reported as the mean +/- standard deviation values.
Article and documents
View on PubMed
Materials (2)

Plastic and Polymer (Sheet)