Yusuf Kanca; Piers Milner; Daniele Dini; Andrew A. Amis
Journal of the Mechanical Behavior of Biomedical Materials Volume 82, June 2018, Pages 394-402
https://doi.org/10.1016/j.jmbbm.2018.04.001
39 citations · 9 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
This research investigated the in-vitro wear and friction performance of polycarbonate urethane (PCU) 80A as they interact with articular cartilage, using a customised multidirectional pin-on-plate tester. Condyles were articulated against PCU 80A discs (Bionate I and Bionate II) (configuration 1) and the results arising from these tests were compared to those recorded during the sliding of PCU pins against cartilage plates (configuration 2). Configuration 1 produced steadily increasing coefficient of friction (COF) (up to 0.64 +- 0.05) and had the same trend as the cartilage–on–stainless steel articulation (positive control). When synovial fluid rather than bovine calf serum was used as lubricant, average COF significantly decreased from 0.50 +- 0.02–0.38 +- 0.06 for condyle–on–Bionate I (80AI) and from 0.41 ± 0.02–0.24 ± 0.04 for condyle–on–Bionate® II (80AII) test configurations (p < 0.05). After 15 h testing, the cartilage–on–cartilage articulation (negative control) tests showed no cartilage degeneration. However, different levels of cartilage volume loss were found on the condyles from the positive control (12.5 +- 4.2 mm3) and the PCUs (20.1 +- 3.6 mm3 for 80 AI and 19.0 +- 2.3 mm3 for 80AII) (p > 0.05). A good correlation (R2 =0.84) was found between the levels of average COF and the volume of cartilage lost during testing; increasing wear was found at higher levels of COF. Configuration 2 showed low and constant COF values (0.04 +- 0.01), which were closer to the negative control (0.03 +- 0.01) and significantly lower than configuration 1 (p < 0.05). The investigation showed that PCU is a good candidate for use in hemiarthroplasty components, where only one of the two articulating surfaces is replaced, as long as the synthetic material is implanted in a region where migrating cartilage contact is achieved. Bionate II showed better tribological performance, which suggests it is more favourable for use in hemiarthroplasty design.
Utilisation des équipements
Le Mach-1 Mechanical Tester a caractérisé le module en compression non confinée et la relaxation des contraintes de disques de polycarbonate uréthane entre plateaux imperméables, en solution saline. Son rôle concernait la caractérisation mécanique des éprouvettes polymères. Le frottement et l’usure entre cartilage et polymère étaient étudiés séparément avec un tribomètre multidirectionnel pion-sur-plan conçu sur mesure.
Matériaux (1)

Matériau
Hydrogel
Configurations de test (1)
Configuration de test