Iman Kafian-Attari; Ervin Nippolainen; Dmitry Semenov; Markku Hauta-Kasari; Juha Töyräs; Isaac O. Afara
Biomedical Optics Express. 2020.
https://doi.org/10.1364/boe.402929
22 citations · 6 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
Absorption and reduced scattering coefficients ( μ a , μ s ‘ ) of biological tissues have shown significant potential in biomedical applications. Thus, they are effective parameters for the characterization of tissue integrity and provide vital information on the health of biological tissues. This study investigates the potential of optical properties ( μ a , μ s ‘ ) for estimating articular cartilage composition and biomechanical properties using multivariate and machine learning techniques. The results suggest that μa could optimally estimate cartilage proteoglycan content in the superficial zone, in addition to its equilibrium modulus. While μ s ‘ could effectively estimate the proteoglycan content of the middle and deep zones in addition to the instantaneous and dynamic moduli of articular cartilage.
Utilisation des équipements
Un Mach-1 V500css mesurait les propriétés mécaniques du cartilage patellaire bovin avec un indenteur plat de 1 mm. Les échantillons ostéochondraux alignés subissaient une relaxation par paliers puis un chargement sinusoïdal à 1 Hz. Les modules instantané, à l’équilibre et dynamique étaient comparés aux mesures optiques et à la composition.
Matériaux (1)