Tiffany Teen Yu Huang; Selma Elekdag-Turk; Oyku Dalci; Mohammed Almuzian; Ersan Ilsay Karadeniz; Carmen Gonzales; Peter Petocz; Tamer Turk; M Ali Darendeliler
European Journal of Orthodontics, 39(5), 547–553, 2017.
https://doi.org/10.1093/ejo/cjw073
10 citations · 1 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
Objective
Various factors have been examined in the literature in an attempt to reduce the incidence and severity of root resorption. The purpose of the present investigation is to test the null hypothesis that there is no difference in relation to force level using gradually increasing (ascending) and decreasing (descending) orthodontic force generated by magnets on the severity of Orthodontically Induced Inflammatory Iatrogenic Root Resorption (OIIRR) and amount of tooth movement.
Methods
Twenty maxillary first premolars from 10 patients were subjected to ascending (25-225 g, magnets in attraction) and descending (225 to 25 g, magnets in repulsion) buccal forces using a split mouth design over an 8-week period. Polyvinyl siloxane impressions were taken at week 0, 4, and 8 to record the tooth movement. After 8 weeks, the teeth were extracted, scanned, with micro-CT in 16.9 µm resolution, and the root resorption craters were localized circumferentially and quantified at each level of the root.
Results
The total volume of OIIRR with ascending force was 1.20 mm3, and with descending force was 1.25 mm3, and there was no statistically significant difference between them. OIIRR on the palatal surface (0.012 mm3) was significantly less than on the buccal surface (0.057 mm3) and than on the mesial surface (0.035 mm3). There is no statistically significant difference in the degree of OIIRR between different level of the root (cervical, middle, and apical) at different surfaces. Moreover, the amount of tooth movement, at 0-, 4-, and 8-week interval, secondary to an ascending and descending force application was not statistically significant.
Conclusions
There is no short-term (8 weeks) statistically significant difference between orthodontic ascending and descending forces, from 25 to 225 g and from 225 to 25 g, respectively, in term of severity and location of OIIRR as well as the amount of tooth movement. The buccal surface of the root showed highest degree of OIIRR compared to other root's surfaces.
Utilisation des équipements
La machine d’essai universelle Mach-1, équipée d’un capteur de force de 10 kg et d’un montage personnalisé, a caractérisé les forces entre deux aimants néodyme-fer-bore. Les mesures débutaient au contact des aimants pour caractériser la relation force–distance des attaches orthodontiques, et non les propriétés mécaniques des dents.
Matériaux (1)