The effect of intermittent static biaxial tensile strains on tissue engineered cartilage

  • par garon@biomomentum.com

Jackie C. Y. Fan; Stephen D. Waldman
Annals of Biomedical Engineering 38(4), 1672–1682 (2010). Complete original abstract retrieved from PubMed PMID 20087771 through Europe PMC. Exact article methods read in author-deposited text indexed on ResearchGate (Stephen D. Waldman); no local article PDF obtained. The thickness and indentation/relaxation characterization are separate from dead-weight biaxial stimulation. This is not the Fan thesis or the later JoVE protocol. Donor species remains unassigned pending the original sample-preparation section. Month precision comes from publisher citation metadata; no fabricated day.

https://doi.org/10.1007/s10439-010-9917-5

39 citations · 1 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Mechanical stimulation of engineered cartilage constructs is a commonly applied method used to accelerate tissue formation and improve the mechanical properties of the developed tissue. While the effects of compression and shear have been widely studied, the effect of tension has received relatively little attention. As articular cartilage in vivo is subjected to a degree of static tension (pre-tension) even in the absence of externally applied loads, the purpose of this study was to investigate the effect of intermittent static biaxial tensile strains (BTS) on chondrocyte metabolism and resultant tissue formation. Using a custom-design loading fixture to apply BTS, the optimal conditions for stimulating extracellular matrix synthesis were under average magnitudes of 3.8% radial and 2.1% circumferential tensile strains for 30 min. Tissue constructs subjected to tensile strain stimulation 3 times/week for a period of 4 weeks displayed increased thickness (35 +/- 18%) and proteoglycan content (22 +/- 7%) without an associated change in mechanical properties. In contrast, constructs stimulated daily over the same time period exhibited negligible effects in terms of ECM accumulation suggesting that the frequency of stimulation needs to be precisely controlled. The results of this study demonstrate that while tension can be used as potential biomechanical stimulus to improve tissue formation, further optimization of this process needs to be conducted to improve ECM accumulation and tissue mechanical properties after long-term exposure to tensile stimuli.

Utilisation des équipements

Un Mach-1 mesurait l’épaisseur et la rigidité compressive à l’équilibre des constructions par indentation uniaxiale non confinée, avec indenteur plat et relaxation par paliers. La stimulation statique biaxiale utilisait un montage distinct chargé par poids morts.

Matériaux (1)

Configurations de test (2)

Découvrez la recherche en pratique

Découvrez les études de cas