Structure-function of cartilage in osteoarthritis: An ex-vivo correlation analysis between its structural, viscoelastic and frictional properties

  • par garon@biomomentum.com

Luisa de Roy; Graciosa Quelhas Teixeira; Jonas Schwer; Matthias Sukopp; Martin Faschingbauer; Anita Ignatius; Andreas Martin Seitz
Acta Biomaterialia 190 (2024), 293–302. Available online 18 October 2024. Original publisher PDF, CC BY, deposited with the German National Library. Original English abstract copied in full. The user confirmed local-normal 3D indentation. Confined compression used a Zwick Z10 and friction used a separate tribometer.

https://doi.org/10.1016/j.actbio.2024.10.027

17 citations · 17 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Healthy articular cartilage is characterized by extremely low friction and high compressive stiffness. This dual-functionality is tailored by its biphasic structure, whereby a fluid phase interacts with the extracellular matrix. Osteoarthritis (OA) causes structural changes, thereby altering the biomechanical and frictional properties. How the structural and functional properties of human cartilage are associated with OA remain unknown. To address this, we identified relationships between structural parameters, viscoelastic and frictional properties of degenerated human cartilage through correlation analyses. We found that cartilage friction was mainly influenced by its microscopic structure, while the viscoelastic properties were also related to the macroscopic structure. The viscoelastic and frictional properties displayed a weak correlation. These findings provide insights into the interplay between cartilage structure and its functional properties in OA, which might provide a basis for advancements in diagnosing and treating degenerated human cartilage.

Utilisation des équipements

Un Mach-1 v500css réalisait l’indentation normale et la relaxation à quatre positions sur le cartilage arthrosique de plateaux tibiaux humains immergés dans le PBS. Un indenteur sphérique de rayon 1 mm appliquait 0,2 mm d’indentation suivie d’un maintien de 600 s. L’utilisateur confirme la fonction 3D; compression confinée et friction utilisaient d’autres appareils.

Matériaux (2)

Configurations de test (2)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.