Quantifying the Effects of Different Treadmill Training Speeds and Durations on the Health of Rat Knee Joints

  • par garon@biomomentum.com

Jaqueline Lourdes Rios; Kevin Rudi Boldt; James William Mather; Ruth Anne Seerattan; David Arthur Hart; Walter Herzog
Sports Medicine – Open 2018 4:15

https://doi.org/10.1186/s40798-018-0127-2

27 citations · 4 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Background Walking and running provide cyclical loading to the knee which is thought essential for joint health within a physiological window. However, exercising outside the physiological window, e.g. excessive cyclical loading, may produce loading conditions that could be detrimental to joint health and lead to injury and, ultimately, osteoarthritis. The purpose of this study was to assess the effects of a stepwise increase in speed and duration of treadmill training on knee joint integrity and to identify the potential threshold for joint damage. Methods Twenty-four Sprague-Dawley rats were randomized into four groups: no exercise, moderate duration, high duration, and extra high duration treadmill exercise. The treadmill training consisted of a 12-week progressive program. Following the intervention period, histologic serial sections of the left knee were graded using a modified Mankin Histology Scoring System. Mechanical testing of the tibial plateau cartilage and RT-qPCR analysis of mRNA from the fat pad, patellar tendon, and synovium were performed for the right knee. Kruskal-Wallis testing was used to assess differences between groups for all variables. Results There were no differences in cartilage integrity or mechanical properties between groups and no differences in mRNA from the fat pad and patellar tendon. However, COX-2 mRNA levels in the synovium were lower for all animals in the exercise intervention groups compared to those in the no exercise group. Conclusions Therefore, these exercise protocols did not exceed the joint physiological window and can likely be used safely in aerobic exercise intervention studies without affecting knee joint health.

Utilisation des équipements

Le Mach-1 Mechanical Tester (v500css) a réalisé une cartographie automatisée par indentation avec relaxation des contraintes du cartilage des plateaux tibiaux de rats. Un indenteur sphérique et un capteur de force multiaxial étaient associés à un système de repérage par caméra dans du PBS. Le module de Young était calculé en 11 sites sur chacun des plateaux médial et latéral pour évaluer la mécanique du cartilage après entraînement sur tapis roulant.

Matériaux (2)

Configurations de test (2)

Produits (1)

Découvrez la recherche en pratique

Découvrez les études de cas