Aller au contenu

Optimization of In Situ Indentation Protocol to Map the Mechanical Properties of Articular Cartilage

  • par garon@biomomentum.com

Matteo Berni; Paolo Erani; Nicola Francesco Lopomo; Massimiliano Baleani
NIH, Materials (Basel). Published: 16 Sep 2022

https://doi.org/10.3390/ma15186425

5 citations · 3 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract
Tissue engineering aims at developing complex composite scaffolds for articular cartilage repair. These scaffolds must exhibit a mechanical behavior similar to the whole osteochondral unit. In situ spherical indentation allows us to map the mechanical behavior of articular cartilage, avoiding
removal of the underlying bone tissue. Little is known about the impact of grid spacing, indenter diameter, and induced deformation on the cartilage response to indentation. We investigated the impact of grid spacing (range: a to 3a, where a is the radius of the contact area between cartilage and indenter), indenter diameter (range: 1 to 8 mm), and deformation induced by indentation (constant indentation depth versus constant nominal deformation) on cartilage response. The bias induced by indentations performed in adjacent grid points was minimized with a 3a grid spacing.
The cartilage response was indenter-dependent for diameters ranging between 1 and 6 mm with a nominal deformation of 15%. No significant differences were found using 6 mm and 8 mm indenters. Six mm and 8 mm indenters were used to map human articular cartilage with a grid spacing equal to 3a. Instantaneous elastic modulus E0 was calculated for constant indentation depth and constant nominal deformation. E0 value distribution did not change significantly by switching the two indenters, while dispersion decreased by 5–6% when a constant nominal deformation was applied.
Such an approach was able to discriminate changes in tissue response due to doubling the indentation rate. The proposed procedure seems to reduce data dispersion and properly determine cartilage mechanical properties to be compared with those of complex composite scaffolds.
Keywords
knee; bovine, human, cartilage, osteochondral unit, mechanical properties, mapping, indentation, in vitro, experimental procedure.

Utilisation des équipements

Le Mach-1 était utilisé pour les essais d’indentation in situ du cartilage articulaire maintenu immergé dans du PBS.

Article et documents

Matériaux (1)

Configurations de test (3)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.