Abstract:

Polydimethylsiloxane (PDMS) is widely used in biomedical devices. Despite its well-recognized hemocompatibility, elasticity, and overall stability, it remains prone to bacterial colonization, which can lead to severe infections and even to device failure. Hydrogenated amorphous carbon (a-C:H) coatings have emerged as a versatile route to enhance biomaterial surfaces, and can serve as platforms for the controlled release of antibacterial agents. However, adhesion of a-C:H coatings to soft polymers such as PDMS remains a critical bottleneck limiting clinical success. This study investigates how substrate bias and hydrogen incorporation during plasma-enhanced chemical vapor deposition affect adhesion, morphology, and interface integrity of a-C:H coatings on PDMS. Coatings deposited without bias were termed polymer-like carbon (PLC), and those deposited at −300 V as diamond-like carbon (DLC). The incorporation of hydrogen during deposition produced the hydrogenated counterparts, PLCH (non-biased + H₂) and DLCH (biased + H₂). Time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling revealed thicker coatings and sharper interfaces for non-biased coatings. In contrast, biased coatings were thinner and showed evidence of intermixing with substrate components. Regarding hydrogen incorporation, a decrease in coating thickness and surface roughness was observed, as well as a 65.5 % reduction in crack density comparing PLC and PLCH after tensile deformation. Furthermore, immersion tests under pseudo-physiological conditions demonstrated that PLCH remained stable for 21 days, with only localized cracks and no significant delamination under either static or dynamic conditions. These results suggest that these coatings can withstand physiological stresses while maintaining mechanical integrity. Therefore, among the variants studied, PLCH emerges as the most promising coating for flexible PDMS-based biomedical devices, offering an optimal balance of thickness, adhesion, flexibility, and chemical durability.

Keywords:

Polydimethylsiloxane; Hydrogenated amorphous carbon; Coatings; Diamond-like carbon; Polymer-like carbon; Plasma-enhanced chemical vapor deposition; Adhesion.

Utilisation des équipements

Le Mach-1 Mechanical Tester a étiré des éprouvettes de PDMS revêtues, en forme d’haltère, pour évaluer leur réponse apparente en traction et enregistrer la force maximale à la déformation prescrite. Le PDMS non revêtu servait de témoin. La fissuration des revêtements était examinée séparément par microscopie optique après déchargement. L’essai ne déterminait ni le module intrinsèque ni la résistance à la traction du revêtement, la réponse étant dominée par le substrat.

Matériaux (1)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.