Delphine Périé; Nagib Dahdah; Anthony Foudis; Daniel Curnier
BMC Cardiovascular Disorders. 2013;13(1):24.
https://doi.org/10.1186/1471-2261-13-24
7 citations · 0 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
Editorial summary
Excised porcine cardiac tissue was examined using multiparametric magnetic resonance imaging followed by uniaxial tensile testing. The investigators assessed relationships between MRI-derived parameters and Young’s modulus, then applied principal component analysis to reduce correlated variables. Direct regression accounted for only part of the measured variation in stiffness, while the dimensionality-reduction approach summarized a larger portion of variation across the combined measurements. The work explores an indirect imaging-based assessment of myocardial material properties in vitro. It does not establish a validated noninvasive stiffness measurement for patients or demonstrate diagnostic accuracy in vivo.
Utilisation des équipements
Note de référencement — Tissus cardiaques in vitro : essais de traction uniaxiale jusqu’à rupture avec un système Mach-1.
Matériaux (1)