Colostomy, a procedure that redirects fecal matter to an external bag, often causes physical and psychological chal lenges [1]. Emerging biomedical technologies aim to develop continence devices that enable bag-free periods, improving patients’ quality of life. To this purpose, this study focused on morphostructural (19 patients)/mechanical (8 patients) characterization of human large bowel (LB) obtained from patients undergoing abdominal surgery for benign conditions at Padova University Hospital (Ethics Approval: CESC Code AOP3212). These analyses are required to support the devel opment of realistic computational models that are essential for accurately simulating tissue- device interaction, which is critical for optimizing device design. The mean thicknesses of different tissue layers were: 669.7 ± 331.5 μm, mucosa; 18.5 ± 8.5 μm, muscularis mucosae; 1173.1 ± 705.7 μm, submucosa; 1813.5 ± 433.4 μm, circular muscle layer; and 1209.2 ± 617.8 μm, longitudinal muscle layer. In parallel, collagen content in the submucosa was evaluated using semi- quantitative analy sis of Azan-Mallory–stained sections via ImageJ software. Col lagen quantification was expressed as the percentage of image area occupied by collagen relative to the total image area (% = collagen area / total area × 100), yielding an average of 51.16% ± 7.91. Mechanical testing was performed (Mach-1 system, ©Biomomentum) on samples oriented along three directions: longitudinal (L, n=8), circumferential (C, n=20), and radial (R, n=12). After preconditioning, L and C samples underwent tensile testing either to failure (strain rate: 100%/s) or under stress-relaxation (SR) conditions (six 30% strain ramps; strain rate: 100%/s; 600 s rest). R samples were subjected to compres sion protocols, including loading-unloading (LU: 60% strain, 1%/s, 10 cycles) and SR (six 10% strain ramps; 100%/s; 600 s rest). For tensile tests, key parameters were calculated from stress- strain curves: ultimate tensile strength (UTS), failure strain (FS), and both initial (Ei) and final elastic moduli (Ef), corresponding to the toe and quasi-linear regions, respec tively. From SR tests, equilibrium relative stiffness (γ∞) was determined as the final normalized stress. LU tests yielded values for Ei, Ef, and peak stress (PS). Results highlighted the mechanical behavior of LB tissue as anisotropic, non-linearly elastic, and time-dependent. Key parameters in each direction were: UTS [kPa]: 427 ± 173 (L), 588±290 (C) and – (R); FS [-]: 2.46 ± 0.72 (L), 3.30 ± 1.50 (C) and – (R); PS [kPa]: – (L), – (C) and 12.13±1.98; Ei [kPa]: 20±17 (L), 18±13 (C) and 0.85±0.34 (R); Ef [kPa]: 485±259 (L), 278±93 (C) and 147±74 (R) ; γ∞ [-]: – (L), 0.12±0.02 (C), 0.07±0.02 (R). The study provided the basis for a visco-hyperelastic constitutive model of fiberreinforced materials, enabling accurate simulation of LB tissue mechanics for the design of advanced continence devices.

Utilisation des équipements

Un Mach-1 caractérisait le côlon humain en traction longitudinale et circonférentielle et en compression radiale. Les protocoles de rupture en traction, chargement–déchargement et relaxation évaluaient l’anisotropie, la rigidité non linéaire et la réponse temporelle pour modéliser les interactions avec des dispositifs de continence.

Article et documents

Matériaux (1)

Configurations de test (3)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.