Adam M. Butler; William R. Walsh
Foot & ankle international, 25(1), 8-12. (2004)
https://doi.org/10.1177/107110070402500103
23 citations · 1 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
BACKGROUND: The aim of this study was to examine the mechanical behavior of human ankle ligaments at low forces. Predominantly, ankle ligaments have been studied under the auspices of ligament injury. While the mechanical properties of a ligament when tested to failure provide a basis for comparisons, the loads and displacement do not reflect normal physiologic loading.
METHODS: Eight fresh-frozen ankles (mean age 65) were dissected to expose the ligaments surrounding the talocrural joint. Eight ankle ligaments were studied and included: medially-anterior tibiotalar (ATTL), posterior tibiotalar (PTTL), tibiocalcaneal (TCL); laterally-anterior tibiofibular (ATiFL), posterior tibiofibular (PTiFL), anterior talofibular (ATFL), posterior talofibular (PTFL), and calcaneofibular (CFL). Stress relaxation tests were carried out at 30% and 10% strain. The peak load and area under the curve were assessed for all experiments.
RESULTS: Significant differences were found for the average peak loads of the elastic response between 30% and 10% strain for each ligament (p < .05). At 10% strain the relationship between the ligaments on the medial and lateral side revealed a Pearson R value of .991 (p = .087). No significant difference was found between the strain energies of the various ligaments (p > .05). The anterior talofibular ligament was found to possess similar relaxation results to the medial ligaments. The calcaneofibular ligament relaxed up to 10% more compared to the anterior talofibular for the same relaxation period. The mechanical testing was performed in uniaxial tension and did not consider off-axis loading that may occur in vivo during ankle motion.
CONCLUSIONS: The stress relaxation experiments revealed all ligaments to relax even when loaded to less than 5 N, reflecting the viscoelastic nature of ligaments.
Utilisation des équipements
Des ligaments de cheville humaine ont subi des essais de relaxation des contraintes en traction uniaxiale pour caractériser leur comportement mécanique sous faibles forces. La charge maximale et l’aire sous la courbe ont été évaluées; le chargement hors axe n’a pas été étudié. Le résumé disponible précise le mode d’essai, mais pas l’appareil; l’attribution au Mach-1 Mechanical Tester ne peut être vérifiée.
Matériaux (1)

Matériau
Ligament et tendon
Configurations de test (1)
Configuration de test