Mechanical loading of knee articular cartilage induced by muscle contraction can be assessed by measuring electrical potentials at the surface of the knee

  • par garon@biomomentum.com

Lin Zhu; Michael D. Buschmann; Pierre Savard
Journal of biomechanics, 49(3), 338-343. (2016)

https://doi.org/10.1016/j.jbiomech.2015.12.033

6 citations · 2 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Electroarthrography (EAG) consists of recording electrical potentials on the knee surface that originate from streaming potentials within articular cartilage while the joint is undergoing compressive loading. The aim was to investigate how the contraction of specific leg muscles affects the contact force of the knee joint and, in turn, the EAG values.
For six normal subjects, voluntary isometric muscle contractions were repeatedly conducted to activate four leg muscle groups while the subject was lying on his back. Two EAG signals were recorded on the medial and lateral sides of the knee, as well as four EMG signals (gastrocnemius, hamstring, quadriceps, tensor fascia latae), and the signal from a force plate fixed against the foot according to the direction of the force.
The EAG and force signals were very well correlated: the median of the correlation coefficients between an EAG signal and the corresponding force signal during each loading cycle was 0.91, and 86% of the correlation coefficients were statistically significant (P<5%). Isolated muscle contraction was possible for the gastrocnemius and hamstring, but not always for the quadriceps and tensor fascia latae. Using the clinical loading protocol which consists of a one-legged stance, the quadriceps and hamstring EMGs showed minimal activity; loading cycles with increased EAG amplitude were associated with higher EMG activity from the gastrocnemius, which is involved in antero-posterior balance.
These results document the role of the EAG as a “sensor” of the knee contact force and contribute to the development of clinical loading protocols with improved reproducibility.

Utilisation des équipements

Des signaux d’électroarthrographie à la surface du genou ont été enregistrés pendant des contractions isométriques volontaires des muscles de la jambe, avec électromyographie et mesures de force par une plateforme placée contre le pied. Ce montage étudiait les signaux électriques liés au cartilage sous charge articulaire d’origine musculaire. Le résumé et l’extrait PDF disponibles n’identifient pas Arthro-BST comme composant du système de mesure.

Article et documents

Matériaux (2)

Configurations de test (1)

Produits (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.