Mechanical Characterization of the Male Lower Urinary Tract: Comparison among Soft Tissues from the Same Human Case Study

  • par garon@biomomentum.com

Alice Berardo; Maria Vittoria Mascolini; Chiara Giulia Fontanella; Martina Contran; Martina Todesco; Andrea Porzionato; Veronica Macchi; Raffaele De Caro; Rafael Boscolo-Berto; Emanuele Luigi Carniel
Applied Sciences. 2024; 14(4):1357. Published: 7 February 2024

https://doi.org/10.3390/app14041357

15 citations · 12 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract

Background: Nowadays, a challenging task concerns the biomechanical study of the human lower urinary tract (LUT) due to the variety of its tissues and the low availability of samples. Methods: This work attempted to further extend the knowledge through a comprehensive mechanical characterization of the male LUT by considering numerous tissues harvested from the same cadaver, including some never studied before. Samples of the bladder, urethra, prostate, Buck’s fascia and tunica albuginea related to corpora cavernosa were considered and distinguished according to testing direction, specimen conformation and anatomical region. Uniaxial tensile and indentation tests were performed and ad hoc protocols were developed. Results: The tissues showed a non-linear and viscoelastic response but different mechanical properties due to their specific functionality and microstructural configuration. Tunica albuginea longitudinally displayed the highest stiffness (12.77 MPa), while the prostate transversally had the lowest one (0.66 MPa). The minimum stress relaxation degree (65.74%) was reached by the tunica albuginea and the maximum (88.55%) by the bladder. The prostate elastic modulus was shown to vary according to the presence of pathological changes at the microstructure. Conclusions: This is the first experimental work that considers the mechanical evaluation of the LUT tissues in relation to the same subject, setting the basis for future developments by expanding the sample population and for the development of effective in silico models to improve the solutions for most LUT pathologies.

Keywords:

lower urinary tract; human soft tissue; urethral tissues; mechanical tests; prostate; bladder; tunica albuginea; Buck’s fascia.

Utilisation des équipements

Le Mach-1 v500csst a caractérisé des tissus humains du bas appareil urinaire par traction uniaxiale, relaxation en traction et indentation sphérique de la prostate. Une cellule uniaxiale de 250 N mesurait les forces. Le protocole ne confirme pas une cartographie d’indentation selon la normale locale 3D.

Matériaux (1)

Configurations de test (3)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.