Quenneville E.; Garon M.; Légaré A.; Buschmann M.D
Transactions of the Orthopedic Research Society. 29: 659.
Les titres, résumés et légendes des publications sont présentés en anglais.
Abstract — Editorial summary
This conference study examined how indentation speed changes cartilage load and streaming-potential responses. Measurements with an instrumented spherical tip showed that force and electrical signals increased together at lower speeds, then approached a plateau above approximately 500 micrometres per second under the tested conditions. Saline concentration strongly influenced the electrical response. Spatial potential profiles were consistent with the changing distribution of fluid flow and pressure beneath the tip. The results provide experimental support for poroelastic load bearing and help explain why loading conditions must be controlled when interpreting probe measurements.
Editorial synthesis based on the source text; not the authors’ verbatim abstract. Read the original source.
Utilisation des équipements
Travaux historiques utilisant des réseaux de microélectrodes ou une première sonde arthroscopique pour étudier l’électromécanique du cartilage. Le dispositif décrit précède le Benchtop Arthro-BST actuel.