The aim of this study is to investigate the impact of the stiffness and stress relaxation of poly(acrylamide-co-acrylic acid) hydrogels on the osteogenic differentiation of human mesenchymal stem cells (hMSCs). Varying the amount of the crosslinker and the ratio between the monomers enabled the obtainment of hydrogels with controlled mechanical properties, as characterized using unconfined compression and atomic force microscopy (AFM). Subsequently, the surface of the hydrogels was functionalized with a mimetic peptide of the BMP-2 protein, in order to favor the osteogenic differentiation of hMSCs. Finally, hMSCs were cultured on the hydrogels with different stiffness and stress relaxation: 15 kPa – 15%, 60 kPa – 15%, 140 kPa – 15%, 100 kPa – 30%, and 140 kPa – 70%. The cells on hydrogels with stiffnesses from 60 kPa to 140 kPa presented a star-like shape, typical of osteocytes, which has only been reported by our group for two-dimensional substrates. Then, the extent of hMSC differentiation was evaluated by using immunofluorescence and by quantifying the expression of both osteoblast markers (Runx-2 and osteopontin) and osteocyte markers (E11, DMP1, and sclerostin). It was found that a stiffness of 60 kPa led to a higher expression of osteocyte markers as compared to stiffnesses of 15 and 140 kPa. Finally, the strongest expression of osteoblast and osteocyte differentiation markers was observed for the hydrogel with a high relaxation of 70% and a stiffness of 140 kPa.

Utilisation des équipements

Le Mach-1 a caractérisé des hydrogels de poly(acrylamide-co-acide acrylique) en compression non confinée pour mesurer leur module élastique et la relaxation des contraintes. Ces mesures ont permis de comparer les propriétés mécaniques des différentes formulations.

Matériaux (1)

Configurations de test (2)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.