E. Marchionatti; A. Desrochers; N. Wenzlow; I. Villemure; C.L. Theoret
Journal of Dairy Science, 2020
https://doi.org/10.3168/jds.2019-17250
3 citations · 1 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
ABSTRACT
Sole ulcers are reportedly one of the most prevalent diseases associated with lameness in dairy cattle, significantly affecting animal welfare and farm profitability. The degree to which sole soft tissues, healthy or ulcerated, are able to maintain their structure and function when subjected to compressive forces remains unknown. Therefore, the aims of the present study were to assess sole tissue biomechanics in healthy and ulcerated claws and to describe correlated histology. Cylindrical samples were harvested from zones 4 and 6, as described by the international foot map, from hind lateral healthy (n = 12) and ulcerated bovine claws (n = 8; animals n = 12). Tissue biomechanics and morphology were evaluated via compressive tests and hematoxylin-eosin-phloxine-saffron staining, respectively. A 2-sample t-test was used to compare zones' mechanical properties between healthy and ulcerated tissues, and the Cochran-Mantel-Haenszel test was used to measure the effect of claw zone on histology. The fibril modulus (Ef) and permeability (k) respectively increased and decreased in ulcerated claws (Ef = 0.201 ± 0.104 MPa; k = 0.128 ± 0.069 mm2/MPa·s) compared with healthy claws (Ef = 0.105 ± 0.050 MPa; k = 0.452 ± 0.365 mm2/MPa·s) only for zone 6. Histology scores equal to or greater than 3 were associated with macroscopic presence of ulceration. A higher proportion of adipose tissue (30% or more) was associated with zone 6 compared with zone 4, but no difference was seen between healthy and ulcerated claws. Ulcerated claws had a higher prevalence of exostoses compared with healthy ones (33% vs. 8%). Sole soft tissues showed, as hypothesized, a viscoelastic behavior using unconfined compression testing, which, however, may not reflect in vivo loading conditions. Clinical and histological signs of sole ulceration were not associated with decreased strength of the supportive apparatus of the distal phalanx in zone 4 in this study.
Key words
dairy cow, sole ulcer, biomechanics, histology, claw supportive apparatus
Note
The fibril network reinforced biphasic model (Korhonen et al., 2003) was fitted to the data to obtain the fibril modulus (Ef) and permeability (k) using the Mach-1 analysis software (Biomomentum Inc.).
Utilisation des équipements
Le logiciel d’analyse Mach-1 a servi à ajuster un modèle biphasique renforcé par un réseau fibrillaire aux données de compression non confinée de tissus de la sole d’onglons bovins sains et ulcérés, afin d’obtenir le module fibrillaire et la perméabilité. Le rôle documenté de Biomomentum concerne l’analyse des données; l’extrait disponible ne précise pas l’appareil ayant réalisé les essais.
Matériaux (1)

Matériau