Impact of Blood Rheology On Transition to Turbulence and Wall Vibration Downstream of a Stenosis

  • par garon@biomomentum.com

Rayanne Pinto Costa; Blaise Simplice Talla Nwotchouang; Junyao Yao; Dipankar Biswas; David Casey; Ruel McKenzie; Frederick Sebastian; Rouzbeh Amini; David A. Steinman; Francis Loth
ASME. J Biomech Eng, Published: October 4, 2022

https://doi.org/10.1115/1.4055856

0 citations · 0 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract
Previous experimental flow studies have demonstrated a delay (~20%) in transition to turbulence for whole blood compared to a Newtonian analog fluid in both a straight pipe and eccentric stenosis model with ridged walls. The impact of wall compliance on the transition to turbulence of blood compared to Newtonian analog and on wall vibration is unknown. The present study employed flexible walls downstream of an eccentric stenosis model and examined the wall vibration during the transition to turbulence with whole blood and a Newtonian analog. Measurements of tube wall vibration velocity (WVV) were used as an indicator of the turbulence level within the flexible tube. WVV was measured at 5, 10, and 15 diameters downstream of the stenosis using a laser Doppler vibrometer at Reynolds numbers 0, 200, 300, 350, 400, 450, 500, 550, 600, 650, 700, and 750. The root mean squares (RMS) of the measured WVV were utilized as an indirect measure of fluid velocity fluctuations present at that location, and hence, an indicator of transition to turbulence. WVV RMS was near-constant until approximately Reynolds number 400. It increased monotonically with Reynolds number for both whole blood and the Newtonian fluid. No differences in the transition to turbulence were observed between whole blood and the Newtonian fluid, as the WVV RMS curves were remarkably similar in shape. This result suggests that rheology had minimal impact on the WVV downstream of a stenosis for transition to turbulence since the fluids had a similar level of vibration.
Keywords
Blood, Rheology, Turbulence, Vibration, Fluids, Reynolds number, Delays, Flow (Dynamics), Fluctuations (Physics), Laser Doppler vibrometers, Pipes & Shapes.

Utilisation des équipements

Un vibromètre laser Doppler a mesuré la vitesse de vibration de la paroi d’un tube en aval d’une sténose excentrée, dans un modèle d’écoulement à paroi souple utilisant du sang total et un fluide analogue newtonien. Ces mesures servaient d’indicateur de turbulence. Le résumé disponible ne précise aucun rôle ni protocole d’un appareil d’essai mécanique pour caractériser les parois du tube.

Article et documents

Matériaux (2)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.