Aller au contenu

Generating Mechanically Stable, Pediatric, and Scaffold-Free Nasal Cartilage Constructs In Vitro

  • par garon@biomomentum.com

Pedram Akbari; Stephen D. Waldman; Evan J. Propst; Sharon L. Cushing; Joanna F. Weber; Herman Yeger; Walid A. Farhat
Tissue Engineering Part C: Methods.2016;22(12):1077–1084. .

https://doi.org/10.1089/ten.tec.2016.0223

5 citations · 1 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Traditional methods of cartilage tissue engineering rely on the use of scaffolds. Although successful chondrogenesis has been reported in scaffold-based constructs, the use of exogenous materials has limited their application due to eliciting host immunogenic responses and potentially resulting in construct failure. As a result, tissue engineering approaches, which aim to generate scaffold-free cartilaginous constructs, have become of particular interest. Here, we generated stable three-dimensional scaffold-free cartilaginous constructs by cultivating expanded pediatric nasal chondrocyte multilayers in a slow turning lateral vessel bioreactor system under chemically defined media. Bioreactor cultivation resulted in increased construct cellularity, fourfold tissue thickness, and 200% sulfated glycosaminoglycan deposition with respect to static culture equivalent cultures. These improvements led to significantly enhanced mechanical and biochemical properties of bioreactor-cultivated constructs, allowing them to support their own weight, while static culture constructs remained fragile. Consequently, bioreactor-cultivated constructs closely resembled native nasal cartilage tissue histologically, mechanically, and biochemically. We propose that this method of cartilage construct formation could be used to obtain readily available human scaffold-free cartilaginous constructs.

Utilisation des équipements

Un système d’essais micromécaniques Mach-1 équipé d’une cellule de charge de 1 kg a servi à tester du cartilage nasoseptal natif et des constructions nasales sans échafaudage. Une double indentation compressive avec des indenteurs à extrémité plane de 2 et 4 mm a permis de déterminer le module élastique et le coefficient de Poisson.

Matériaux (1)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.