Ferrofluid microrobot driven by an adjustable magnetic tweezer for soft tissue mechanical measurement

  • par garon@biomomentum.com

Zhaokai Wang; Zihuan Wu; Heidi-Lynn Ploeg; Shideh Kabiri Ameri; Yongjun Lai; Na Liu; Xian Wang
Microsyst Nanoeng 12, 180, Published: 14 May 2026

https://doi.org/10.1038/s41378-026-01314-0

0 citations · 0 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract

Quantitative mapping of tissue mechanical properties is essential for understanding disease progression and guiding therapeutic interventions. However, conventional techniques are constrained by limited spatial coverage and poor mechanical compliance between rigid probes and soft biological tissues. Here, we report an adjustable magnetic tweezer microsystem that actuates a 1 mm vegetable oil–based ferrofluid droplet for in situ mechanical measurement with high spatial coverage and accuracy. The system features a tunable workspace (9–80 mm) that enables two operational modes: large-scale magnetic field gradients for droplet navigation and localized uniform fields for controlled deformation. The ferrofluid’s fluid-like compliance facilitates soft–soft interaction with tissue, reducing artifacts from probe stiffness mismatch. Quantitative tests across sucrose solutions (0.8–83 mPa·s) and agar gels (0.4–142 kPa) showed agreement with viscometer and indentation standards (with all errors under 10%, except for the case with 1 mPa·s viscosity, where the Brownian motion at the low viscosity affects the accuracy). The method was further validated in biological tissue, demonstrating 1.6% deviation from reference measurements. This integrated ferrofluid–magnetic tweezer platform provides a minimally invasive, compliance-matched approach for viscoelastic characterization of soft materials and tissues.

Utilisation des équipements

La section de méthode mentionne un appareil Mach-1 et décrit des essais de indentation et de mesure locale.

Les détails du protocole sont conservés en anglais dans cette rubrique; consulter la publication originale pour le contexte expérimental complet.

Matériaux (1)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.