Electrospun composite-coated endotracheal tubes with controlled siRNA and drug delivery to lubricate and minimize upper airway injury

  • par garon@biomomentum.com

Solaleh Miar; Gabriela Gonzales; Gregory Dion; Joo L. Ong; Ronit Malka; Rena Bizios; Ryan C. Branski; Teja Guda
Biomaterials, Volume 309, 2024, 122602, ISSN 0142-9612.

https://doi.org/10.1016/j.biomaterials.2024.122602

10 citations · 10 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract:

Endotracheal Tubes (ETTs) maintain and secure a patent airway; however, prolonged intubation often results in unintended injury to the mucosal epithelium and inflammatory sequelae which complicate recovery. ETT design and materials used have yet to adapt to address intubation associated complications. In this study, a composite coating of electrospun polycaprolactone (PCL) fibers embedded in a four-arm polyethylene glycol acrylate matrix (4APEGA) is developed to transform the ETT from a mechanical device to a dual-purpose device capable of delivering multiple therapeutics while preserving coating integrity. Further, the composite coating system (PCL-4APEGA) is capable of sustained delivery of dexamethasone from the PCL phase and small interfering RNA (siRNA) containing polyplexes from the 4APEGA phase. The siRNA is released rapidly and targets smad3 for immediate reduction in pro-fibrotic transforming growth factor-beta 1 (TGFϐ1) signaling in the upper airway mucosa as well as suppressing long-term sequelae in inflammation from prolonged intubation. A bioreactor was used to study mucosal adhesion to the composite PCL-4APEGA coated ETTs and investigate continued mucus secretory function in ex vivo epithelial samples. The addition of the 4APEGA coating and siRNA delivery to the dexamethasone delivery was then evaluated in a swine model of intubation injury and observed to restore mechanical function of the vocal folds and maintain epithelial thickness when observed over 14 days of intubation. This study demonstrated that increase in surface lubrication paired with surface stiffness reduction significantly decreased fibrotic behavior while reducing epithelial adhesion and abrasion.

Keywords:

Endotracheal tube; SMAD3; Local drug delivery; siRNA delivery; Upper airway.

Utilisation des équipements

Le Mach-1 Mechanical Tester a évalué les caractéristiques de frottement du revêtement des sondes endotrachéales et la rigidité locale du tissu laryngé lésé, avec des configurations distinctes de capteurs de force. Pour les essais de rigidité, les demi-larynx étaient fixés dans des moules en plâtre et immergés dans du PBS. L’indentation sphérique à des points prédéfinis des plis vocaux fournissait les courbes force–déplacement utilisées pour déterminer la rigidité tissulaire.

Matériaux (1)

Configurations de test (3)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.