Chen Jin; Rui Zhu; Meng-lei Xu; Liang-dong Zheng; Hui-zi Zeng; Ning Xie; Li-ming Cheng
Frontiers in Bioengineering and Biotechnology. 2022;10:762555.
https://doi.org/10.3389/fbioe.2022.762555
6 citations · 2 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
Editorial summary
Freshly excised rat spinal cord specimens retaining the pia and arachnoid were tested by indentation to examine the effects of loading speed and contact size. Three indenter radii and several loading rates were used to characterize peak force, relaxation and apparent stiffness at small deformations. The response was nonlinear and time dependent. Increasing speed increased apparent stiffness, whereas a larger contact area changed the response differently, demonstrating that test geometry and rate must both be considered. The findings provide experimental data for understanding spinal cord mechanics and interpreting models of traumatic injury.
Utilisation des équipements
Note de référencement — Moelle épinière : essais ex vivo d’indentation et de relaxation avec le Mach-1 V500css.