Digital image correlation guided wearable sensor design and fabrication of novel microfluidic pump for human movement classification using machine learning models

  • par garon@biomomentum.com

Nick Cmager
Thesis, 2024. Repository: https://scholarcommons.scu.edu/bioe_mstr/14/

Les titres, résumés et légendes des publications sont présentés en anglais.

Wearable technologies are transforming healthcare and enabling physicians to customize treatments through continuous non-invasive data acquisition. Microfluidic sensors have been gaining attention due to their flexibility and ability to conform to the human skin. However, individual variations in skin properties necessitate personalized sensor designs. This thesis presents a novel approach for designing and fabricating wearable microfluidic sensors, leveraging digital image correlation (DIC) to guide the development of a microfluidic pump for human movement classification. An open-source DIC platform Ncorr was utilized for 2D and 3D DIC analysis of human skin strain. The results were used to guide the design of a novel skin-strain-actuated microfluidic pump (SAMP) that employs asymmetric aspect ratio channels to record human activity in the fluidic domain. The passive image-based data readout method eliminates the need for electronics. An analytical model was established describing the SAMP’s operation mechanism as a wearable microfluidic device. A series of benchtop experiments established SAMP’s capability of measuring hundreds of strain cycles. Human experiments confirmed proof-of-concept by quantifying simple wrist flexion and distinguishing between complex shoulder movements. Finally, a theoretical method for improving the movement classification by utilizing machine learning models was discussed.

Utilisation des équipements

Un Mach-1 de Biomomentum a appliqué une déformation cyclique en traction à des pompes microfluidiques en PDMS maintenues par des pinces. Des photographies ont suivi le déplacement du liquide pour caractériser l’efficacité du pompage selon la géométrie des canaux et la déformation. Ces essais étaient distincts des expériences humaines et des analyses DIC.

Article et documents

Matériaux (1)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.