Aller au contenu

Determination of nonlinear fibre-reinforced biphasic poroviscoelastic constitutive parameters of articular cartilage using stress relaxation indentation testing and an optimizing finite element analysis

  • par garon@biomomentum.com

A. Seifzadeh; D.C.D. Oguamanam; N. Trutiak; M. Hurtig; M. Papini
Computer Methods and Programs in Biomedicine. 2012.

https://doi.org/10.1016/j.cmpb.2011.07.004

45 citations · 2 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

An inverse method was developed to determine the material constitutive parameters of human articular cartilage from stress relaxation indentation tests. The cartilage was modeled as a fibre-reinforced nonlinear biphasic poroviscoelastic material, and a finite element (FE) model was used with a simulated annealing (SA) optimization algorithm to determine the material parameters that minimized the error between the experimental and predicted time dependant indentation loads. The values of the 15 optimized material parameters were found to be insensitive to the initial guesses, and, when friction between the indenter and the cartilage was considered, resulted in good agreement between the measured stress relaxation response and the FE prediction (R(2)=0.99). The optimized material parameters determined from experiments that used two different indenter sizes on the same samples were compared. When assuming frictionless contact between the indenter and the cartilage, all of the optimized parameters except for the Poisson's ratio were found to be relatively insensitive to indenter size. A second set of models that included frictional contact greatly reduced the sensitivity of the optimized Poisson's ratio to indenter size, thus confirming the validity of the model and demonstrating the importance of modeling friction. The results also demonstrate the robustness of the SA optimization algorithm to ensure convergence of a large number of material properties to a global minimum regardless of the quality of the initial guesses.

Utilisation des équipements

Un Mach-1 avec cellule de 10 N réalisait des indentations à axe fixe avec relaxation et indenteurs cylindriques plats. Une rotule réglée manuellement orientait la surface perpendiculairement à l’indenteur; il ne s’agit pas de l’indentation normale 3D automatisée.

Matériaux (1)

Configurations de test (2)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.