Aller au contenu

Correlation of Non-destructive Electromechanical Probe (Arthro-BST) Assessment with Histological Scores and Mechanical Properties in Human Tibial Plateau

  • par garon@biomomentum.com

Sim S; Chevrier A; Garon M; Quenneville E; Buschmann MD
Orthopeadic Research Society Annual Meeting in Las Vegas, 2015, Poster 1228

0 citations · 0 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

The purpose of the study was to investigate if electromechanical properties of human tibial plateau correlate strongly with histological scores and with biomechanical properties as in human distal femurs (Sim et al., 2014). Six pairs of tibial plateau from human donors (5 males and 1 female, average age 48 years) were provided by RTI Surgical (FL, USA). Ex vivo electromechanical properties were mapped across entire articular surfaces using the Arthro-BST. The device calculates a quantitative parameter (QP) which corresponds to the number of microelectrodes in contact with the cartilage when the sum of their streaming potential reaches 100 mV (inversely proportional to electromechanical activity). A total of 56 osteochondral cores were then harvested to be tested in unconfined compression to obtain the fibril modulus (Ef), equilibrium modulus (Em), and permeability (k) prior to histoprocessing. Safranin O-Fast Green-stained paraffin sections were assessed with the Mankin score. The QP corresponding to the cored site was calculated as the average of all QPs measured within 6 mm from the core center. Safranin O-Fast Green-stained sections showed a decrease in matrix GAG staining and worse structural integrity as the QP increased as expected (Fig.1). The QP decreased with increasing Ef (r = −0.73, p<0.0001; Fig.2A) and Em (r=−0.30, p=0.0186; Fig.2C) whereas the QP increased with Mankin Score (r=0.50, p=0.0004), permeability (r=0.64, p<0.0001; Fig.2B) and thickness (r=0.42, p=0.0006; Fig.2D). Similar correlations of the QP with histological score and mechanical parameters were observed in human tibial plateau as in distal femurs, thus reinforcing the interpretation of QP as an accurate assessment of cartilage quality. In addition, there was a positive correlation between QP and cartilage thickness, which could be related to variations present on the tibial plateau surface. Considering these results, we believe that the Arthro-BST can provide a reliable tool.

Utilisation des équipements

Arthro-BST a cartographié ex vivo les propriétés électromécaniques de l’ensemble des surfaces articulaires de plateaux tibiaux humains. Son paramètre quantitatif (QP) correspond au nombre de microélectrodes en contact lorsque la somme des potentiels d’écoulement atteint 100 mV. Les valeurs locales de QP ont été comparées aux scores histologiques et aux propriétés mécaniques de carottes ostéochondrales testées en compression non confinée. Les méthodes fournies n’identifient pas l’appareil de compression.

Article et documents

Matériaux (2)

Configurations de test (2)

Produits (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.