Contrast-Enhanced Computed Tomography (CECT) attenuation is associated with stiffness of intact knee cartilage

  • par garon@biomomentum.com

Reza Nickmanesh; Rachel C. Stewart; Brian D. Snyder; Mark W. Grinstaff; Bassam A. Masri; David R. Wilson
J. Orthop. Res. First published: 17 April 2018

https://doi.org/10.1002/jor.24022

12 citations · 3 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Contrast‐enhanced computed tomography (CECT) using charged contrast‐agents enables quantification of cartilage glycosaminoglycan content. Since glycosaminoglycan content is a key determinant of cartilage compressive stiffness, CECT measurements have the potential to non‐invasively assess cartilage stiffness. The objective of this study was to determine whether CECT attenuation, using a cationic contrast‐agent (CA4+), correlates with the stiffness of intact cartilage. Six fresh femoral and six fresh tibial compartments with intact cartilage were obtained from patients undergoing total knee replacement surgery. The instantaneous stiffness was determined for 25–50 points on the surface of each compartment using an established indentation technique. The samples were then immersed in CA4+ solution for 48 h, scanned in a micro‐CT scanner, and the average CECT attenuation at each indentation site was found for the superficial cartilage. A significant (p < 0.01) and positive correlation was observed between stiffness and CECT attenuation for sites from each individual cartilage surface, with correlation coefficients ranging from r = 0.37–0.57 and r = 0.48–0.69 (p < 0.01) for the tibia and femur, respectively. When data for each type of cartilage surface were pooled together, the correlation coefficients were r = 0.73 for femoral condyle data points and r = 0.49 for tibial plateau data points. CECT provided a map of cartilage stiffness across each surface, which allows regions of low stiffness to be identified. These findings support continued evaluation and development of quantitative imaging techniques to assess the functional properties of cartilage.

Utilisation des équipements

Le Mach-1 Mechanical Tester (v500css) a cartographié la rigidité par indentation de compartiments cartilagineux fémoraux et tibiaux humains intacts prélevés lors d’arthroplasties du genou. L’orientation locale de la surface était mesurée à chaque site, puis le mouvement coordonné de trois axes faisait avancer l’indenteur sphérique perpendiculairement à celle-ci. La force et le déplacement normaux fournissaient les mesures de rigidité comparées à l’atténuation tomodensitométrique avec contraste aux sites correspondants.

Matériaux (2)

Configurations de test (2)

Produits (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.