Aapo Ristaniemi; Juuso Tuppurainen; Jiri Jäntti; Ervin Nippolainen; Isaac O. Afara; Mika E. Mononen; Rami K. Korhonen; Janne T.A. Mäkelä
Journal of Biomechanics, Volume 177, 2024, 112386, ISSN 0021-9290, Available online 28 October 2024
https://doi.org/10.1016/j.jbiomech.2024.112386
7 citations · 7 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
Abstract:
Site-specific differences in the compressive properties of tibiofemoral joint articular cartilage are well-documented, while exploration of tensile and frictional properties in humans remains limited. Thus, this study aimed to characterize and compare the tensile, compressive and frictional properties of articular cartilage across different sites of the tibiofemoral joint, and to establish relationships between these properties and cartilage degeneration. We cut human tibiofemoral joint (N = 5) cartilage surfaces into tensile testing samples (n = 155) and osteochondral plugs (n = 40) to determine the tensile, friction and compressive properties, as well as OARSI grades. We performed comparisons between sites using a linear mixed model and analyzed relationships with OARSI grade using Spearman’s rank correlation. Cartilage samples were mostly healthy: 56 % were grade 0 or 1, 26 % grade 2, and 18 % grade 3 or higher. In tension, the medial femur was more compliant and viscous compared to the lateral femur (p < 0.05). In compression, the lateral tibia exhibited a lower equilibrium modulus than both femoral condyles (p < 0.05), while the initial friction coefficient was higher in the medial tibia compared to both femoral condyles (p < 0.05). We found no significant correlation between tensile or friction properties and OARSI grade, while compressive properties deteriorated with increasing OARSI grade. The observed site-specific differences in cartilage properties in tension, compression, and friction, demonstrate adaptations to different loading experienced by the surfaces. The comprehensive set of properties presented in this study are valuable for improving future computational knee joint models and serving as a reference for tissue engineering and prosthetic implants.
Keywords:
Tibiofemoral joint; Cartilage; Tensile properties; Compressive properties; Friction.
Utilisation des équipements
Le Mach-1 Mechanical Tester a caractérisé en traction le cartilage tibiofémoral humain à l’aide de mors sur mesure. Le protocole associait relaxation des contraintes par paliers, chargement sinusoïdal et essai final quasi statique jusqu’à rupture. Ces mesures évaluaient le comportement viscoélastique et la rupture en traction ; les méthodes fournies n’attribuent pas les essais de compression ou de frottement à cet instrument.
Matériaux (1)
