Légaré A; Garon M; Binette F; Guardo R; Savard P; Buschmann MD
Transactions 5th Canadian Connective Tissue Conference. Montreal, Canada, June 1999.
Les titres, résumés et légendes des publications sont présentés en anglais.
Abstract — Editorial summary
This presentation explored relationships between matrix composition and electromechanical behaviour in cartilage and meniscus. Interleukin-1α-treated cartilage was compared with controls using biochemical assays, mechanical tests and spatial streaming-potential maps. Degradation reduced glycosaminoglycan content, increased collagen damage and lowered both stiffness and electrical response. Peripheral electrical changes appeared early. Separate meniscus measurements showed regional variation and substantially lower responses than articular cartilage. The work illustrates how spatial electrical mapping can characterize connective-tissue function and support development of an arthroscopic assessment approach.
Editorial synthesis based on archived conference presentation; not the authors’ verbatim abstract.
Utilisation des équipements
Travaux historiques utilisant des réseaux de microélectrodes ou une première sonde arthroscopique pour étudier l’électromécanique du cartilage. Le dispositif décrit précède le Benchtop Arthro-BST actuel.
Matériaux (1)