Aller au contenu

Characterisation of the mechanical properties of infarcted myocardium in the rat under biaxial tension and uniaxial compression

  • par garon@biomomentum.com

Mazin S. Sirry; J. Ryan Butler; Sourav S. Patnaik; Bryn Brazile; Robbin Bertucci; Andrew Claude; Ron McLaughlin; Neil H. Davies; Jun Liao; Thomas Franz
Journal of the Mechanical Behavior of Biomedical Materials. 2016.

https://doi.org/10.1016/j.jmbbm.2016.06.029

49 citations · 8 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Understanding the passive mechanical properties of infarcted tissue at different healing stages is essential to explore the emerging biomaterial injection -based therapy for myoc ardial infarction (MI). Although rats have been widely used as animal models in such investigations, the data in literature that quantify the passive mechanical properties of rat heart infarcts is very limited. MI was induced in rats and hearts were harves ted immediately (0 day), 7, 14 and 28 days after infarction onset. Left ventricle anterioapical samples were cut and underwent equibiaxial and non equibiaxial tension followed by uniaxial compression mechanical tests. Histological analysis was conducted to confirm MI and to quantify the size of the induced infarcts. Infarcts maintained anisotropy and the nonlinear biaxial and compressive mechanical behaviour throughout the healing phases with the circumferential direction being stiffer than the longitudinal direction. Mechanical coupling was observed between the two axes in all infarct groups. The 0, 7, 14 and 28 days infarcts showed 438, 693, 1048 and 1218 kPa circumferential tensile moduli. The 28 day infarct group showed a significantly higher compressive modulus compared to the other infarct groups (p= 0.0060, 0.0293, and 0.0268 for 0, 7 and 14 days groups). Collagen fibres were found to align in a preferred direction for all infarct groups supporting the observed mechanical anisotropy. The presented data are useful for developing material models for healing infarcts and for setting a baseline for future assessment of emerging mechanical-based MI therapies.

Utilisation des équipements

Un Mach-1 réalisait la compression uniaxiale locale de myocarde infarci de rat, avec un indenteur plat de 2,7 mm à quatre sites jusqu’à 30 % de déformation dans du PBS. Les essais de traction biaxiale utilisaient un montage distinct.

Matériaux (1)

Configurations de test (1)

Découvrez la recherche en pratique

Découvrez les études de cas

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.