Jan C. Schagemann; Nicola Rudert; Michelle E. Taylor; Sotcheadt Sim; Eric Quenneville; Martin Garon; Mathias Klinger; Michael D. Buschmann; Hagen Mittelstaedt
Cartilage. 2016 Oct; 7(4): 346-60. .
https://doi.org/10.1177/1947603515623992
Les titres, résumés et légendes des publications sont présentés en anglais.
Objective
To compare the regenerative capacity of 2 distinct bilayer implants for the restoration of osteochondral defects in a preliminary sheep model.
Methods
Critical sized osteochondral defects were treated with a novel biomimetic poly-ε-caprolactone (PCL) implant (Treatment No. 2; n = 6) or a combination of Chondro-Gide and Orthoss (Treatment No. 1; n = 6). At 19 months postoperation, repair tissue (n = 5 each) was analyzed for histology and biochemistry. Electromechanical mappings (Arthro-BST) were performed ex vivo.
Results
Histological scores, electromechanical quantitative parameter values, dsDNA and sGAG contents measured at the repair sites were statistically lower than those obtained from the contralateral surfaces. Electromechanical mappings and higher dsDNA and sGAG/weight levels indicated better regeneration for Treatment No. 1. However, these differences were not significant. For both treatments, Arthro-BST revealed early signs of degeneration of the cartilage surrounding the repair site. The International Cartilage Repair Society II histological scores of the repair tissue were significantly higher for Treatment No. 1 (10.3 ± 0.38 SE) compared to Treatment No. 2 (8.7 ± 0.45 SE). The parameters cell morphology and vascularization scored highest whereas tidemark formation scored the lowest.
Conclusion
There was cell infiltration and regeneration of bone and cartilage. However, repair was incomplete and fibrocartilaginous. There were no significant differences in the quality of regeneration between the treatments except in some histological scoring categories. The results from Arthro-BST measurements were comparable to traditional invasive/destructive methods of measuring quality of cartilage repair.
Utilisation des équipements
Le Benchtop Arthro-BST a servi à cartographier ex vivo les propriétés électromécaniques des condyles fémoraux ovins traités et controlatéraux non traités. Une compression manuelle avec repérage par caméra fournissait les valeurs locales du paramètre quantitatif QP. Des cartes diagnostiques de référence évaluaient la réparation cartilagineuse et la dégénérescence autour des sites réparés.
Matériaux (2)

Cartilage articulaire